MAX32600 User’s Guide
Analog Front End
8.2 AFE Reconfiguration Matrix
• 0: Op Amp Mode
• 1: Comparator Mode
AFE_CTRL5.op_cmp_b
Field
Bits
Default
Access
Description
op_cmp_b
25
0
R/W
Mode Select for Op Amp B
• 0: Op Amp Mode
• 1: Comparator Mode
AFE_CTRL5.op_cmp_c
Field
Bits
Default
Access
Description
op_cmp_c
26
0
R/W
Mode Select for Op Amp C
• 0: Op Amp Mode
• 1: Comparator Mode
AFE_CTRL5.op_cmp_d
Field
Bits
Default
Access
Description
op_cmp_d
27
0
R/W
Mode Select for Op Amp D
• 0: Op Amp Mode
• 1: Comparator Mode
Rev.1.3 April 2015
Maxim Integrated
Page 402