MAX32600 User’s Guide
Communication Peripherals
7.4 USB Device Interface
USB_DEV_CN.fifo_mode
Field
Bits
Default
Access
Description
fifo_mode
9
0
R/W
FIFO Mode
This register bit, when set, configures the device controller to respond to an incoming IN request as soon as the device controller’s FIFO become non-empty, instead
of waiting for the full packet to be received by the FIFO. Setting this bit to 1 reduces the likelihood of returning NAK. This is the recommended setting.
7.4.4.1.4
USB_DEV_INTFL
USB_DEV_INTFL.dpact
Field
Bits
Default
Access
Description
dpact
0
0
W1C
DPLUS Activity Interrupt Flag
This interrupt flag indicates that activity has been detected on the DPLUS (D+) USB interface pin.
Set to 1 by hardware when the associated interrupt condition has been detected. Write 1 to clear.
USB_DEV_INTFL.rwu_dn
Field
Bits
Default
Access
Description
rwu_dn
1
0
W1C
Remote Wakeup Done Interrupt Flag
This interrupt flag indicates that the remote wakeup signalling to the USB bus host has been completed.
Set to 1 by hardware when the associated interrupt condition has been detected. Write 1 to clear.
USB_DEV_INTFL.bact
Field
Bits
Default
Access
Description
bact
2
0
W1C
USB Bus Activity Interrupt Flag
Rev.1.3 April 2015
Maxim Integrated