MAX32600 User’s Guide
Communication Peripherals
7.1 I²C
Filter frequency = 200MHz/bits[7:0]; 1=Off
I2CMn_FS_CLK_DIV.fs_scl_lo_cnt
Field
Bits
Default
Access
Description
fs_scl_lo_cnt
19:8
12’b0
R/W
Full Speed SCL Low Count
Number of clocks to hold SCL low for clock output
I2CMn_FS_CLK_DIV.fs_scl_hi_cnt
Field
Bits
Default
Access
Description
fs_scl_hi_cnt
31:20
12’b0
R/W
Full Speed SCL High Count
Number of clocks to hold SCL high for clock output
7.1.8.1.2
I2CMn_TIMEOUT
I2CMn_TIMEOUT.tx_timeout
Field
Bits
Default
Access
Description
tx_timeout
23:16
8’b0
R/W
Transaction Timeout Limit
Timeout limit (in mS) for a given transaction; when this timeout expires, master releases the bus and triggers an interrupt.
I2CMn_TIMEOUT.auto_stop_en
Field
Bits
Default
Access
Description
auto_stop_en
24
0
R/W
Auto-Stop Enable
Rev.1.3 April 2015
Maxim Integrated
Page 231