G. GAS INFORMATION
It is your responsibility to have
ALL
plumbing connections made by a qualified professional to assure that the gas
plumbing installation is adequate and conforms with local and state regulations or codes. In the absence of such
codes,
ALL
plumbing connections, materials, and workmanship
must conform
to the applicable requirements of the
National Fuel Code ANSI Z223.1-LATEST EDITION or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or
CAN.CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing),
as well as local codes and ordinances and
must be
done by qualified professional.
IMPORTANT:
Failure to comply with these codes or ordinances, and/or the requirements stipulated
in this manual, can result in personal injury and improper operation of the dryer.
The dryer and its individual shutoff valve
must be
disconnected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The dryer
must be
isolated from the gas supply
piping system by closing its individual manual shutoff valve during any pressure test of the gas supply system at test
pressures equal to or less than 1/2 psig (3.5 kPa).
IMPORTANT:
Failure to isolate or disconnect dryer from supply as noted can cause irreparable
damage to the gas valve VOIDING THE WARRANTY.
WARNING: FIRE OR EXPLOSION COULD RESULT
.
1. Gas Supply
The gas dryer installation
must meet
the American National Standard … National Fuel Gas Code ANSI Z223.1-
LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas)
or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and
must be
done by a qualified professional.
NOTE:
Undersized gas piping will result in ignition problems, slow drying, increased use of energy,
and can create a safety hazard.
The dryer
must be
connected to the type of heat/gas indicated on the dryer data label. If this information does
not agree with the type of gas available,
DO NOT operate the dryer
.
Contact the reseller who sold the dryer or
the factory.
IMPORTANT:
Any burner changes or conversions
must be
made by a qualified professional.
The input ratings shown on the dryer data label are for elevations up to 2,000 feet (609.6 meters) unless elevation
requirements of over 2,000 feet (609.6 meters) were specified at the time the dryer order was placed with the
factory. The adjustment or conversion of dryers in the field for elevations over 2,000 feet (609.6 meters) is made
by changing each burner orifice. If this conversion is necessary, contact the reseller who sold the dryer or contact
the factory.
IMPORTANT:
This gas dryer
is not
provided with an internal gas supply shutoff and an external gas
supply shutoff
must be
provided.
Summary of Contents for MAXI200
Page 16: ...12 113261 1 1 DOOR 2 WAY TILT...
Page 19: ...113261 1 15 1 DOOR FORWARD TILT...
Page 22: ...18 113261 1 2 DOOR REAR TILT PASS THRU...
Page 25: ...113261 1 21 1 DOOR 2 WAY TILT...
Page 28: ...24 113261 1 1 DOOR FORWARD TILT...
Page 31: ...113261 1 27 2 DOOR REAR TILT PASS THRU...
Page 37: ...113261 1 33...
Page 38: ...34 113261 1...
Page 39: ...113261 1 35...
Page 78: ...Part No 113261 1 09 20 10 0...