Maxell MXFC-1000 Instruction Manual Download Page 1

Table of contents

Safety Precautions
Feature of the product
Skin compatible check
Device details
Preparation before use

Specification

Disposal of product

2
5
5
6
7

26
27

Instruction Manual

Thank you for buying Maxell product.
Please read this manual to use correct in advance.
Please keep this manual carefully.

1.5hr Rechargeable

Rechargeable Moisturization support device

MXFC-1000

Example for Use

How to Use

Care of the device

FAQs
Trouble Shooting

10
12
22

23
25

1
2
3
4
5
6
7
8

10
11
12
13

PA1215-00

How to keep

22

9

For household use only

Summary of Contents for MXFC-1000

Page 1: ...truction Manual Thank you for buying Maxell product Please read this manual to use correct in advance Please keep this manual carefully 1 5hr Rechargeable Rechargeable Moisturization support device MX...

Page 2: ...use this product This product may cause the medical electronic devices to malfunction Self contained medical electronic devices such as a pacemaker Wearable medical electronic devices such as an elect...

Page 3: ...electric shock may occur Make sure If any unusual sound or abnormality occurs in the main body immediately stop using this product and contact the distributor for repair together with the power adapt...

Page 4: ...ound to your skin Cause of skin trouble or pain Do not drop this product or give it a strong impact Cause of injury or failure Do not wipe with benzene thinner or alcohol and do not spray insecticide...

Page 5: ...If you use skin lotion at first time please check your skin by patch test 1 Please wash your arm by soap and wipe out by towel 2 After washed your arm please apply that new lotion to there then keep 4...

Page 6: ...mp flashing means the sigh of charging request After press Power button 1 2 or 3 lamp lights Device details 4 Thermal head Titanium Vibrate while using except COOL mode Spot sensor When Spot sensor fi...

Page 7: ...d socket Charging lamp Under charging Light up red Completed charging Off Model No KH 55M Attachment Power adaptor Ring 2pcs Ring is for cotton fix to the device Power plug Insert deeply to the socket...

Page 8: ...t Please keep in mind the following to keep enough performance of the battery 1 Please charge before use if you don t use 3 month or over 2 Do not charge each by use 3 Recommendation temperature range...

Page 9: ...ot use cotton and skin lotion Clean skin by washing your face so that makeup and dirt will wash off Please wipe off your makeup with a cleansing product Attach cotton to the Thermal head of the device...

Page 10: ...eup 3 Do not use at same place over 10sec 4 Please change the level to adjust your skin condition You can choose 1 2 and 3 as you like If your skin tingles use the device on 1 If you feel something un...

Page 11: ...6 min Step 1 CLEANSING HOT Step 2 MOISTURIZE HOT Before you go out or when you have more time use MOISTURIZE HOT after using CLEANSING HOT This treatment moisturizes the clean skin thoroughly Daily Tr...

Page 12: ...while using the device stop using it immediately and consult a skin care specialist Cause of accident or poor health Step 1 CLEANSING HOT This mode removes fine residue remaining in pores which canno...

Page 13: ...ating the device is not working If you leave the device as it is for about 3 min without vibration the device will automatically switch Off Automatic shutoff function Notification timer function Skin...

Page 14: ...Power button The level indicator lamp will be turned on and MOISTURIZE HOT on the mode indicator lamp will start flashing If a lamp in another mode is flashing press the mode switch button to switch...

Page 15: ...y and uniformly cared for Apply cotton gently to the face and slowly move the device by sliding it from the center of the face to the outer side Do not keep the cotton on the same area of skin it is n...

Page 16: ...HOT mode it will set HOT MOIST mode automatically after press Power button Select electric level by LEVEL switching button Choose the strength of electrical potential with the Level switch button Swi...

Page 17: ...on Dark Low High Light Add more skin lotion when there is no moisture in the cotton or when the device is difficult to slide Do not apply the device on the same area of skin for less than 10 sec If yo...

Page 18: ...e is finished press the power switch and the MASK HOT mode will automatically be set Choose the strength of electrical potential with the level switch button Switch the strength with the Level switch...

Page 19: ...off automatically Auto off function Notify by End sound Pi Pi Wipe off the surface of the Thermal head with a tissue STEP4 COOL This mode provides cool feeling by the cooling head surface which is ap...

Page 20: ...the light Cooling head does not vibrate Available time to use is 1min 50sec Since you can apply the device to the same area of your skin for only 1sec repeatedly apply the head to your skin on and of...

Page 21: ...ply the head to the skin it will not start to operate Memory function This device has a memory function to memorize of the electrical strength levels of 1 2 and 3 In each usage mode Step 1 to 3 the de...

Page 22: ...and malfunctions of spot sensor After care of the device please attach protective cap on Warm Cool head avoid humidity or dust and lay down horizontal by Thermal head upper then keep Protective cap c...

Page 23: ...act to the distributor Warning sound is made and COOL mode indicator lamp flashing does not stop There are few available times Check charging condition it is out of recommendation temperature range fr...

Page 24: ...annot attach the ring The ring is set upside down Please attach narrow side of inside up to cover the cotton Check charging condition it is out of recommendation temperature range from 10 to 35deg C o...

Page 25: ...roduct be used in the bathroom This product is not waterproof Never use or place this product in wet and damp areas e g bathroom If you still feel uncomfortable on the skin please stop using the produ...

Page 26: ...11 Another case If the device has any abnormal condition please contact to the distributor which is you bought If you still feel uncomfortable on the skin please stop using the product immediately and...

Page 27: ...eyes do not rub eyes but immediately wash them with clean water and then seek for medical consultation If the fluid gets on your body or clothing thoroughly wash it away with clean water and then seek...

Page 28: ...en the body cases front and rear and remove the body case rear Disconnect the lithium ion battery connector and take it out of the battery holder Screw cap Screw Driver Main body Rear Main body Front...

Page 29: ...apping around by code to the body of device and also avoid to keep connecting device plug Cord Do not wrap around the cord to the body Device plug Make sure to pull out the device plug from the main b...

Page 30: ...e heating dimple head of the product to your skin Otherwise the product will not be operated Back plate This product which is operated through the human body The electric circuit operates on skin in c...

Page 31: ......

Reviews: