7-1
SPECIFICATIONS
www.maxcessintl.com
MAGPOWR TLC-B
MI 850A356 1 A
Product
specifications
Warning – Do not use the devices outside of their rated
specifications
Gage resistance
350 ohm
Gage type
Metal foil, full Wheatstone bridge
Excitation voltage
10 VDC maximum
Output signal
1.5 mV/V, 15 mVDC maximum at full
load rating with 10 VDC excitation
IP rating
IP67 with dust seal
IP57 without dust seal
Operating Temperature
-25° C to 80° C [-13° F to 176° F]
Temperature effect on zero
0.02% of rating per ºC
Combined non-linearity and
hysteresis
0.5% of full scale maximum
Repeatability
0.2% of full scale maximum
Overload stops engagement
105% to 150% of full load rating
Overload protection
10X full load rating
Deflection at full load
0.17 mm [0.007 in.]
Cable connector
MAGPOWR mating cable LCC series, or
mating connector Part No. 12B220-1
Climate class
3K3 (EN60721)
Weight
7.3 Kg [16 lbs]
Certification
RoHS
CE
UL (with IS2)