12.0
COMMUNICATION (OPTIONAL)
www.maxcessintl.com
MAGPOWR Spyder-Plus-S1 Tension Control
MI 850A351 1 C
Page 62 of 68
12.7 MODBUS PARAMETER LIST
This table lists all the Spyder parameters and their minimum and maximum values. Modbus register addresses are
shown in hexadecimal format in the table. Control type abbreviations are LC = Load Cell Control, DTND = Dancer
Torque Control No Diameter, DTD = Dancer Torque Control with Diameter, DS = Dancer Speed Control, OPT =
Open Loop Tension based on Diameter Control.
Starting
Modbus
Register
Parameter Name
Parameter
Format
Parameter
Type
Used with
Control Types
Read /
Write
Range
0x01
Use DHCP
BYTE
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
0 = No,
1 = Yes
0x02
IP Address
UINT32
Cal
LC, DTND,
DTD, DS, OPT
Read /
Write
{0.0.0.0 -
255.255.255.255}
0x04
Subnet Mask
UINT32
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
{0.0.0.0 -
255.255.255.255}
0x06
Gateway Address
UINT32
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
{0.0.0.0 -
255.255.255.255}
0x08
FTP Address
UINT32
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
{0.0.0.0 -
255.255.255.255}
0x0A
FTP Program Number
UINT32
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
920Axxx.yyy
xxx,yyy={0 - 999}
xxx = High Word
yyy = Low Word
0x0C
FTP Directory
STRING
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
31 Characters Maximum
0x1C
FTP User Name
STRING
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
31 Characters Maximum
0x2C
FTP Password
STRING
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
31 Characters Maximum
0x3C
Screen Contrast
BYTE
Cal
LC, DTND,
DTD, DS, OPT
Read /
Write
{ 0 - 255 }
0x3D
Language
BYTE
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
0 = English
1 = French
2 = German
3 = Italian
4 = Spanish
0x3E
Remote Setpoint Tension
FLOAT
Data
LC
Read /
Write
{ 0.0 - 99999.0 } lb.
0x40
Setpoint Source
BYTE
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
0 = Analog
1 = Ethernet/Software
0x41
Taper Percent
FLOAT
Data
LC, OPT
Read /
Write
{ 0.0 - 100.0 } %
0x43
Is Taper Setup
BYTE
Cal
LC
Read /
Write
0 = No
1 = Yes
0x44
System Type (Load Cell)
BYTE
Data
LC
Read /
Write
0 = Unwind
1 = Rewind
2 = Type 1
3 = Type 2
4 = Type 3
5 = Type 4
0x45
System Type (Dancer)
BYTE
Data
DTND, DTD,
DS
Read /
Write
0 = Unwind
1 = Rewind
0x46
Control Type
BYTE
Data
LC, DTND,
DTD, DS, OPT
Read /
Write
0 = Load Cell
1 = Dancer, Torque
2 = Dancer, Speed
3 = Tension, Diameter
0x47
Output Range
BYTE
Data
LC, DTND,
DTD, DS
Read /
Write
0 = Normal
1 = -10V to +10V
0x48
Maximum Tension
FLOAT
Cal
LC, DTND,
DTD, DS
Read /
Write
{ 0.0 - 99999.0 } lb.
0x4A
Applied Tension
FLOAT
Cal
LC, DTND,
DTD, DS
Read /
Write
{ 0.0 - 99999.0 } lb.