Maxcess MAGPOWR PS90 Instruction Manual Download Page 1

 

 

PS90 

90 VDC Power Supply

 

Instruction Manual 

 

www.maxcessintl.com 

PS90 

MI 850A264 1 F 

Page 1 of 4 

 

All of the information herein is the exclusive proprietary property of Maxcess International, and is disclosed with 
the understanding that it will be retained in confidence and will neither be duplicated nor copied in whole or in 
part nor be used for any purpose other than for which disclosed. 

 

Copyright 2011, 2018 all rights reserved.  

 

Periodically there will be updates to this manual. The latest version is available on our website or by calling your 
regional office listed on the back page of this publication. 
  

INTRODUCTION 

The MAGPOWR Model PS90 is an isolated controllable current regulator for 90 VDC magnetic 
particle clutches and brakes. The PS90 also provides a small amount of reverse current to minimize 
the drag torque of the clutch / brake. 

The Model PS90 has four jumper selectable current ranges.  Maximum outputs for the individual 
ranges are 0.125, 0.25, 0.5 and 1.0 ADC.  The appropriate range is determined by the current rating 
of the clutch or brake to be controlled.  For best torque control resolution, the lowest current range 
providing sufficient current for maximum operating torque should be selected. 

The PS90 accepts either a remote adjustment potentiometer, or a 0 to 10 VDC analog control signal. 

Connections are provided for an external 1 mADC current meter.  The meter display will indicate 
output current as a percentage of the output range selected. 

The control circuits are electrically isolated from the power circuits. 
 

INSTALLATION 

The PS90 is intended for installation on a vertical panel with a DIN 35 rail, with the wiring terminals 
facing down.  Figure 1 shows the enclosure dimensions. 

 

 

 

 
 

Figure 1. Enclosure Dimensions 

 

6.18 [157.0 mm]

2.30 [58.4 mm]

1.39 [35.2 mm]

3.38 [85.9 mm]