![Maxcess MAGPOWR GTS Load Cell User Manual Download Page 12](http://html1.mh-extra.com/html/maxcess/magpowr-gts-load-cell/magpowr-gts-load-cell_user-manual_1743247012.webp)
4-3
INSTALLATION
www.maxcessintl.com
MAGPOWR GTS Load Cell
MI 850A347 1 A
Top plate adapters
TA1 (installed dimensions)
T-slot top plate adapter
For size ‘A’ metric load cell only
TA2 (installed dimensions)
T-slot top plate adapter
For size ‘A’ metric load cell only
TA3 installed dimensions)
Blank top plate adapter
For size ‘B’ metric load cell only
Top plate adapter kits
Due to the large number of metric pillow blocks, and in
keeping with metric practices, mounting adapter kits are
available for the metric series load cells. Order one kit for
each load cell. Load cells are pre-tapped to receive the
correct adapter kit.
Model
Description
TA1
11 mm T-Slot Kit for GTSAM;
includes 2 rails and four M6 screws
TA2
12 mm T-Slot Kit for GTSAM;
includes 2 rails and four M6 screws
TA3
Blank Top Plate Kit for GTSBM;
includes plate and four M10 screws
18
11
8
12
20
12
10
16
63.5
25.4
GTSAM
LOAD CELL
GTSAM
LOAD CELL
GTSBM
LOAD CELL