4–9
OPERATION
www.maxcessintl.com
MAGPOWR DTR-65
MI 850A349 1 D
Tension calibration
Weightless calibration
continued
Display now shows C2.4. Press [
] and enter the combined
load cell rating. Press and hold [
] for two seconds (until the
display starts flashing) to store the parameter. Range {0,
9990}.
Display will now show C2.5. Press [
] and enter the maximum
tension. Press and hold [
] for two seconds (until the display
starts flashing) to store the parameter. This value scales the
output. The output will be at 10 volts or 20 mA when the
measured tension matches this value. The maximum output
voltage or current is set by parameters P.07, P.09, and P.11.
Range {0, 9990}.
Figure 8. Weightless calibration angles.
X = Web wrap angle
Y = Angle from force direction Arrow
Continued