ENTERING MAXIMUM TENSION
www.maxcessintl.com
DLCA NET-S1
MI 850A374 1 A
Page 29 of 67
6.0
Entering maximum tension
The following are examples of displaying tension that results from
the value entered for maximum tension and the selection of the
decimal point position. The DLCA NET-S1 displays tension with
three significant digits.
Example 1
Using two GTSD-15000M load cells:
The rated load is 30000 kg.
The application’s maximum tension is 15000 kg.
Enter decimal point position as 000.0.
Enter Maximum tension as 15.0.
The DLCA NET-S1 now displays tension with units of 1000 kg.
The display will increment in 100 kg steps.
Same application but desired units are Newtons:
The load cell’s rated load is 294 kN.
The application’s maximum tension is 147 kN.
Enter decimal point position as 0000.
Enter Maximum tension as 147.
The DLCA NET-S1 now displays tension with units of 1 kN.
The display will increment in 1 kN steps.
Same application but desired units are Pounds:
The load cell’s rated load is 66.1 kPounds.
The application’s maximum tension is 33.0 kPounds.
Enter decimal point position as 000.0.
Enter maximum tension as 33.0.
The DLCA NET-S1 will now display tension with units of
1 kPound.
The display will increment in 0.1 kPound steps.
Continued next page