10
Model i-32V5C Midi
Capacity of rubber vubration dampers [daN/mm]
0121, 0126, 0128, 0132
63
BMS connectivity predisposition - ModBus protocol included (CM)
accessory allowing connection of the unit to external controllers via serial cable with RS-485 electrical standard and ModBus RTU protocol.
USB RS485 serial converter (ISK)
Interface device capable of reading and writing control registers via the RS485 standard and converting it to a USB port that can be connected
to any supervisory system.
Gateway Modbus RTU (RS485) to BACnet / Lonworks
device that allows conversion between Modbus RTU and BACnet/Lonworks, allowing the unit control to be configured as a normal device in the
BACnet/Lonworks network.
Gateway Modbus RTU (RS485) to BACnet / Konnex
device that allows conversion between Modbus RTU and BACnet/ Konnex, allowing the unit control to be configured as a normal device in the
BACnet / Konnex network.
7-touch/HUB (Cloud/App)
7-touch/HUB (Cloud/App) is a compact system consisting of an ultra-thin touch panel, including a temperature control unit and gateway for
remote control from a PC (via the "my.maxa.it" portal) or smartphone (via the app downloadable from the "My Maxa" online store). It allows
winter and summer climate control.
Remote touch screen display (Hi-TV415)
remote touch screen control for the centralised management of a chiller/heat pump network, it integrates humidity and
temperature sensors for the thermo-hygrometric analysis of the environment and the management of the double set point
for radiant floor systems that use a dehumidification system.
Remote control (I-Cr)
Modbus remote control with negative LCD and capacitive keys. The device is to be used as a remote machine keyboard with
local temperature detection, replicating the functions of the on-board control.
3. INSTALLATION
All handling, installation and maintenance operations must be carried out by QUALIFIED PERSONNEL only. Before any operation on the unit,
make sure that the power supply is disconnected.
The minimum permissible temperature for storing the units is 5°C.
3.1
UNIT DIMENSIONS,HYDRAULIC CONNECTIONS,WEIGHTS AND CENTRE OF GRAVITY PO
-
SITION
3.1.1 Net dimensions and with packaging
Model i-32V5C Midi
Length A [mm]
Width B [mm]
Height C [mm]
0121
1600
680
1315
0126
1600
680
1315
0128
1600
680
1315
0132
1600
680
1315
Model with packaging
Length [mm]
Width [mm]
Height [mm]
0121
1660
700
1412
0126
1660
700
1412
0128
1660
700
1412
0132
1660
700
1412