Max SuperRoofer CN445R3 Operating And Maintenance Manual Download Page 7

7

3. SPECIFICATIONS AND TECHNI-

CAL DATA

1.

NAME OF PARTS

2.

TOOL SPECIFICATIONS

3.

FASTENER SPECIFICATIONS

TOOL AIR FITTINGS:

This tool uses a 1/4" N.P.T. male plug. The inside diameter should 
be .28" (7 mm) or larger. The fitting must be capable of discharging 
tool air pressure when disconnected from the air supply.

RECOMMENDED OPERATING PRESSURE:

70 to 100 p.s.i. (5 to 7 bar). Select the operating air pressure with-
in this range for best fastener performance. 

DO NOT EXCEED 120 p.s.i. (8 bar).

4.

TECHNICAL DATA

1

NOISE

A-weighted single-event sound power level

------ LWA, 1s, d 100.7 dB

A-weighted single-event emission sound pressure level at 
work station

------ LpA, 1s, d 93.8 dB

These values are determined and documented in accord-
ance to EN12549 : 1999.

2

VIBRATION
Vibration characteristic value = 3.81 m/s2
These values are determined and documented in accord-
ance to ISO 8662-11.
This value is a tool-related characteristic value and does not 
represent the influence to the hand-arm-system when using 
the tool. An influence to the hand-arm-system when using 
the tool will for example depend on the gripping force, the 
contact pressure force, the working direction, the adjust-
ment of mains supply, the workpiece, the workpiece sup-
port.

5.

APPLICATIONS

Fastening asphalt and fiberglass shingles

Siding installation

Fastening lath wire on the plywood

Wooden box assembly

4. AIR SUPPLY AND CONNEC-

TIONS

Read section titled "SAFETY INSTRUCTIONS"

DO NOT USE ANY POWER SOURCE EXCEPT AN AIR COM-
PRESSOR

The tool is designed to operate on compressed air. Do not oper-
ate the tool on any other highpressure gas, combustible gases 
(e.g., oxygen, acetylene, etc.) since there is the danger of an ex-
plosion. For this reason, absolutely do not use anything other 
than an air compressor to operate the tool.

OPERATE WITHIN THE PROPER AIR PRESSURE RANGE

The tool designed to operate within an air pressure range of 70 
to 100 p.s.i.. (5 to 7 bar)
The pressure should be adjusted to the type of the work being 
fastened. The tool shall never be operated when the operating 
pressure exceeds 120 p.s.i.. (8 bar)

DO NOT OPERATE THE TOOL NEAR A FLAMMABLE SUB-
STANCE

Never operate the tool near a flammable substance (e.g., thinner, 
gasoline, etc.). Volatile fumes from these substances could be 
drawn into the compressor and compressed together with the air 
and this could result in an explosion.

DO NOT USE A WRONG FITTINGS

The connector on the tool must not hold pressure when air supply 
is disconnected. If a wrong fitting is used, the tool can remain 
charged with air after disconnecting and thus will be able to drive 
a fastener even after the air line is disconnected, possibly caus-
ing injury.

1

Frame

2

Cylinder Cap

3

Contact Arm

4

Nose

5

Magazine

6

Trigger

7

Grip

8

Exhaust Port

9

Trigger Lock 
Dial

0

Shingle Gauge

a

Swivel Joint

HEIGHT

10-5/8" (271 mm)

WIDTH

4-5/8" (116 mm)

LENGTH

12-3/8" (313 mm)

WEIGHT

5.6 lbs. (2.6 kg)

RECOMMENDED
OPERATING PRESSURE

70 to 100 p.s.i.

(5 to 7 bar)

LOADING CAPACITY

120 Nails

AIR CONSUMPTION

0.046 ft

3

 at 90 p.s.i. (1.3   at 6 bar)

operating pressure

NAIL LENGTH

3/4" to 1-3/4" (19 to 45 mm)

SHANK DIAMETER

.120" (3.0 mm)

SHANK TYPE

Smooth, Ring

9

6

5

10

11

4

2

1

7

3

8

WARNING

Thinner

Gasoline

Summary of Contents for SuperRoofer CN445R3

Page 1: ...STRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE AVANT D UTILISER CET OUTIL LIRE CE MANUEL ET LES CONSIGNES DE S CURIT AFIN DE GARANTIR UN FONCTIONNEMENT S R CONSERVER CE MANUEL E...

Page 2: ...une situation ventuellement dangereuse qui si elle n est pas contourn e pourrait provoquer la mort ou des blessure s rieuses ATTENTION Indique une situation ventuellement dangereuse qui si elle n est...

Page 3: ...1 DEC 1989 and provide both frontal and side protection The employer is responsible to enforce the use of eye pro tection equipment by the tool operator and all other person nel in the work area NOTE...

Page 4: ...bar as the tool can burst 3 DO NOT OPERATE THE TOOL NEAR A FLAMMABLE SUBSTANCE Never operate the tool near a flammable substance e g thinner gasoline etc Volatile fumes from these substanc es could b...

Page 5: ...G THE FASTENERS AFTER COMPLETING OPERATION If fasteners are left in the magazine after the completion of operation there is the danger of a serious accident occur ring prior to the resumption of opera...

Page 6: ...ool Do not use the tool as a hammer Always carry the tool by the grip never carry the tool by the air hose The tool must be used only for the purpose it was designed Never remove tamper with the opera...

Page 7: ...tool is designed to operate on compressed air Do not oper ate the tool on any other highpressure gas combustible gases e g oxygen acetylene etc since there is the danger of an ex plosion For this rea...

Page 8: ...les 2 Do not connect the air supply 3 Inspect screw tightness 4 Check operation of the contact arm trigger if moving smoothly 5 Connect the air supply 6 Check the air leakage The Tool must not have th...

Page 9: ...es If it does not engage check that the nail heads are in the slot on the Nose TEST OPERATION 1 Adjust the air pressure at 70 p s i 5 bar and connect the air supply 2 Without touching the Trigger depr...

Page 10: ...be ignited by a spark causing an explosion Tar and dirt may build up on the Nose and Contact Arm This can prevent correct operation Remove any build up with kerosene 2 fuel oil or diesel fuel Do not...

Page 11: ...ng else while the operator is holding the Trigger pulled SEQUENTIAL TRIP Identified by ORANGE TRIGGER CONTACT TRIP WITH ANTI DOUBLE FIRE MECHANISM Optional kit US patent 5597106 UK patent 2286790 The...

Page 12: ...PERA TION Disconnect air supply and empty the Magazine when inspect ing or maintaining the tool 1 Drain air line filter and compressor 2 Keep lubricator filled in air 3 pieces set 3 Clean filter eleme...

Page 13: ...e the quality of our products Les caract ristiques et la conception des produits mentionn s dans ce manuel sont sujettes des modifications sans pr avis en raison de nos efforts continus pour am liorer...