![Max Machinery 213 Operational Manual Download Page 13](http://html.mh-extra.com/html/max-machinery/213/213_operational-manual_1742941013.webp)
Max Machinery, Inc. 210 Series User Manual © Copyright 2013
Rev. 002Q4
13
Frequency
Single Phase
Wiring
All Other
Models
Mating Cable
Wire Color
Turck
Pin #
Case Ground
Case
Blue
3
Common
Com
Black
4
Power 5-26 Vdc
V+
Brown
1
Pulse Output
Ph A
White
2
N/A
NC
Grey
5
Frequency
Single Phase
* A current sinking device produces an output pulse which is the opposite of a
sourcing device. A positive DC voltage must be applied to the wire running between
PhA and your PLC. When the output is triggered, this voltage will be grounded to
zero volts. Note: use a 5k ohms resistor to limit the current flow in the signal line.
Current Sinking* Wiring
(models 29X-6XX)
All Other Models
Mating Cable
Wire Color
Turck
Pin #
Case Ground
Case
Blue
3
Common
Com
Black
4
Power 5-26 Vdc
V+
Brown
1
Output Phase A
Ph A
White
2
Output Phase B
Ph B
Grey
5
Frequency
Quadrature
Turck Connector
2
1
4
5
3
Electrical Installation - Wiring
Wiring FREQUENCY
The electrical connector versions are pre-wired inside the transmitter and ready to accept a mating cable (available from
the factory). The liquid-tight, NPT models need to be wired during installation as shown in the table below: