defective
replace
Safety valve II blows off
3rd stage valves
Replace
defective
Safety valve III blows off
Maximum operating
Stop compressor,
pressure exceeded
disconnect cylinder
Final safety valve blows
Safety valve not well
Replace safety
off below 210 bar
adjusted
valve
Safety valve 1st or 2nd stage blows
Safety valve defective
Replace safety
off below normal intermediate pressures
valve
Engine speed and output decrease
Engine power insufficient
Adjust v-belt
v-belt
slipping
Output decreases
Valves blocked or leaking
Clean or replace
although engine speed
Damaged piston of 3rd stage
Replace
is correct
Blocked cooling tubes or
Tighten or replace
gaskets leaking
Check; brush with soap,
replace
Intake filter blocked
Replace
Intake hose bent
Readjust
Worn pistons or rings
Replace
Oil taste in delivered air
Activated carbon
Replace
filter
saturated
Compressor gets too hot
Wrong direction of
See arrow on
rotation
compressor
Dirt on outside of cooler
Clean
Dirty valve(s) not closing
Clean or replace
property (causing over-
charge of another stage)
V-belt torn (loose)
Replace (tighten)
Strict observance of the operating instructions increases the life of the compressor and reduces down time.
Gas engine does not start
See operating manual
Electric motor does not start
One phase failed
Check fuses
Safety valve 1 blows off
2nd stage valves
Clean valves or
Page 12 of 22
Trouble Shooting
Trouble Cause Remedy