Matrox Radient eCL acquisition section 45
Camera control and auxiliary signals for Matrox Radient eCL-SF
and eCL-DF
The following tables summarize the auxiliary functionality that the PSGs support,
and the corresponding signals that the PSGs can receive/generate, for Matrox
Radient eCL-SF and eCL-DF. The table also documents the MIL constants to use.
LVDS cam. ctrl
LVDS cam. ctrl
Camera Link
Connector
0
Camera Link
Connector
2
*
*. Only available on Matrox Radient eCL-DF.
M_CC_IO
n
n
1
2
3
4
1
2
3
4
for M_DEV
m
†
†. MIL constant, where
n
and
m
correspond to the number in the row. M_DEV
m
is the required device number
of the digitizer (
MdigAlloc()
) that you must use to access this signal.
m
0
0
0
0
1
1
1
1
Functionality
Ac
qu
is
iti
on
p
at
h
CC
1
CC
2
CC
3
CC
4
CC
1
CC
2
CC
3
CC
4
Timer
(M_TIMER
n
†
)
0
1/2
1/2
1/2
1/2
1
1/2
1/2
1/2
1/2
User output
(bit of Camera Link static-user-output register
M_USER_BIT_CC_IO
n
†
)
0
0/1
0/1
0/1
0/1
1
0/1
0/1
0/1
0/1
Summary of Contents for Radient eCL-DF
Page 6: ......
Page 18: ...18 Chapter 1 Introduction ...
Page 28: ...28 Chapter 2 Hardware installation ...
Page 60: ...60 Chapter 4 Matrox Radient eCL hardware reference ...
Page 66: ...66 Appendix A Glossary ...
Page 86: ...86 Appendix B Technical information ...
Page 95: ...Limited warranty Refer to the warranty statement that came with your product ...
Page 96: ......