3.  Remove the injectors and replace with the corresponding injector 

as shown in the table at the bottom of this page.

Setting up minimum flow rates:

1.  Remove the control knobs.

2.  Turn on the LPG supply, 

light the burners and turn 

the controls to the minimum 

position, as indicated by the 

small flame.

3.  Insert a 2.5mm screwdriver 

into the hole at the top of the 

tap and turn the adjustment screw fully clockwise as shown in fig. 6.

4.  Turn the controls to maximum position then quickly to the minimum 

position - make sure the flame does not extinguish.

5.  Replace the knobs.

LPG to Natural Gas Conversion

This hob can be converted from propane operation at a nominal inlet 

pressure of 37mbar or butane operation at a nominal inlet pressure 

of 28/30mbar to natural gas at 20mbar. This conversion must only be 

carried out by a competent person (i.e. a Gas Safe registered fitter).

Fig.6

Summary of Contents for MHG101

Page 1: ...Gas hob Manual for installation use and maintenance MHG101 parts 1 year labour year guarantee www matrixappliances co uk...

Page 2: ...10 Care And Maintenance 11 Troubleshooting 12 What to do if you smell gas 15 Mains Electricity Connection 16 Technical Information 17 Gas Supply Requirements 18 Ventilation 18 Natural Gas to LPG Conve...

Page 3: ...h reduced physical sensorial or mental capacity or who lack experience or knowledge about it unless they have had supervision or instructions on how to use the appliance by someone who is responsible...

Page 4: ...OF THE PRODUCT IN ACCORDANCE WITH EU DIRECTIVE 2012 19 EU At the end of its working life the product must be taken to a special local authority waste collection centre or to a dealer providing applia...

Page 5: ...is correctly adjusted for the type of gas available before installation The use of a gas appliance produces heat and humidity in the room in which it is installed Ensure that the room is well ventilat...

Page 6: ...Gas Burners 1 Rapid burner 3 0kW 2 Left Semi rapid burner 1 85kW 3 Right Semi rapid burner 1 85kW 4 Auxiliary burner 1 0kW Control knobs 5 Back right 6 Back left 7 Front left 8 Front right Fig 1 5 6 7...

Page 7: ...te the burner in a clockwise direction from the closed position may cause damage to the hob Igniting the gas burners This hob s burners are fitted with flame failure devices These operate by shutting...

Page 8: ...d clicking constantly for more than 15 seconds at a time If a burner does not ignite or turns off accidentally turn the control knob to the closed off position Wait for one minute before attempting to...

Page 9: ...priate burner depending on the size of the pan The most efficient use of the hob is shown below where the pan and burner are correctly chosen Use pan lids where possible to minimize the energy usage o...

Page 10: ...leaners are available The enamelled parts of hobs pan stands and burner caps on this model are not suitable for cleaning in dishwashers They should be washed by hand and dried thoroughly afterwards wi...

Page 11: ...circled in Fig 5 4 Check that the burner caps black metal plates that sit atop the burners are clean and free from grease and debris on both sides IMPORTANT Ensure burners have been allowed to cool b...

Page 12: ...storage vessel s Metered installations shut off the ECV at the meter installation outside the building Cylinder fed installations shut all cylinder valves 2 Extinguish all naked flames Do not smoke i...

Page 13: ...hire boat owners etc may have their own responsibilities in the event of a gas leak so always contact the relevant site owner authority Northern Ireland Natural Gas 0800 002 001 Northern Ireland Gas E...

Page 14: ...Isles are shown below Calor 08457 444 999 BP 0845 607 6118 Flogas 0845 7200 100 Shell 0870 7539 999 Please note The CDA Group Ltd makes no warranty about the content of this section and will not be h...

Page 15: ...the I E T and local regulations This appliance is not suitable for connection to a 13A plug or 13A supply Please note The mains cable must only be replaced by a qualified electrician or service engin...

Page 16: ...necting to the fuse spur proceed as follows The wire which is coloured green and yellow must be connected to the terminal marked E Earth or coloured green The wire which is coloured blue must be conne...

Page 17: ...fe registered fitter requiring help must provide their name address and registration number Information supplied will be validated before help is provided In the event that this appliance is not insta...

Page 18: ...pliances in the same room consult the relevant British Standard BS5440 or GAS SAFE Document Natural Gas to LPG Conversion This hob can be converted from natural gas to propane operation at a nominal i...

Page 19: ...hole at the top of the tap and turn the adjustment screw fully clockwise as shown in fig 6 4 Turn the controls to maximum position then quickly to the minimum position make sure the flame does not ex...

Page 20: ...ood above the hob must be at least 700mm 750mm is recommended Fig 9 If the instructions supplied with the hood dictate that the hood must be installed at a height greater than 700mm then that height i...

Page 21: ...install the hob Overall dimensions of the hob Width 580mm Depth 500mm Worktop cut out dimensions Width 557mm Depth 477mm 1 Make the required hole in the worktop Note that before doing this check the...

Page 22: ...22 Fig 7 Fig 8 Fig 9 Fig 10 Fig 11...

Page 23: ...LA TION EU No 66 2014 B Rational use of the energy and the appliance The gas hob is designed for domestic use only please do not use for commercial purposes The gas hob is designed for use with gas LP...

Page 24: ...or our Customer Care Department or for Service please contact us on Serviced by The CDA Group Ltd Harby Road Langar Nottinghamshire NG13 9HY Tel 01949 862012 Fax 01949 862003 Email customer care cda e...