6
Fuel tank capacity: 6 L
Oil capacity:
0.4 L
5. Layout (B1-B3)
1 12 V DC
2 Fuel cap
3 120 V socket-outlets
4 Earth connection
5 Overload cut-out
6 Voltmeter
7 Oil drain plug
8 Oil filler plug
9 Oil shortage cut-out
10 On/Off switch
11 Choke lever
12 Pull cord
13 Petrol cock
14 Carry handle
15 Air filter set
16 Spark plug
17 Muffler
6. Before Putting the Machine into
Operation
6.1 Electrical Safety
- Electric supply cables and connected equipment
must be in perfect condition.
- The generator is to be operated only with
equipment whose voltage specifications conform
to the generator's output voltage.
- Never connect the generator to the power
supply (socket-outlet).
- Keep the cable length to the consumer as short
as possible.
6.2 Environmental Protection
- Dispose of soiled maintenance material and
operating materials at the appropriate collection
point.
- Recycle packaging material, metal and plastics.
6.3 Grounding
The housing must be grounded in order to
discharge static electricity. To do this, connect one
end of a cable to the ground (4) on the generator
and the other end to an external grounding
device (for example a grounding rod).
7. Operation
Important!
You must fill up with engine oil and fuel before
you can start the engine.
- Check the fuel level and top it up if necessary.
- Make sure the generator has sufficient
ventilation.
- Make sure the ignition cable is secured to the
spark plug.
- Inspect the immediate vicinity of the generator.
- Disconnect any electrical equipment which may
already be connected to the generator.
7.1 Starting the Engine
- Do not connect the power tool before starting
the motor.
- Open the petrol cock (13) by turning it down.
- Move the ON/OFF switch (10) to position "I”.
- Move the choke lever (11) to position IØI.
- Start the engine with the reversing starter (12)
by pulling the handle forcefully. If the engine
does not start, pull the handle again.
- Push the choke lever (11) back again after the
engine has started.
Important!
When starting with the reserve starter, the motor
may recoil suddenly as it starts up, resulting
in hand injuries. Wear protective gloves when
starting the equipment.
7.2 Connecting Consumers to the Generator
Connect the equipment you want to use to the
socket-outlets (3).
Important:
- Do not connect the generator to the domestic