22
PROTON 206/308 V1 System Manual
CAUTION!
For all normal applications, keep this PBX Expansion count to 0 for all the trunks. Otherwise, outside dialing may
be hampered. The PROTON 206/308 supports PBX Expansion count for each trunk.
How to program?
Use following command to program PBX Expansion count for a trunk:
54-Trunk-PEC Count
Trunk is from 1 to 3.
PEC Count is from 0 to 9
By default, PEC for all the trunks is 0.
Example:
To program PEC=1 for trunk 1, dial
54-1-1.
Boss Ring
What’s this?
This feature helps the user to identify the caller. A person in the organization having higher hierarchy can be
assigned this feature. Whenever a person having access to Boss Ring calls any other person in the
organization, the called station rings differently. This helps the called party to identify the caller.
How to program?
Boss Ring is a programmable feature. It can be allowed or denied to a station user. This feature is associated
with feature Raid. Whenever a person having access to Raid makes a call the called station gets Boss Ring.
Please refer
for more details.
Important Point:
•
Boss Ring is same as Alarm Ring.
Relevant Topics:
1.
2.
Busy Hunting Group
What’s this?
In some applications, it is desirable that if the called station is busy, the call should ring on the near by station
instead of giving busy tone to the caller.
How to use it?
Desired stations can be programmed in one group. If the called station is busy then the call will be diverted to
next free station in the group.
How to program?
Use following command to program a station in a busy hunting group:
304-Station-Busy Hunting Group
Where,
Station is from 21 to 28
Busy Hunting Group is from 1 to 9
Use following command to program all stations in a busy hunting group:
304-*-Busy Hunting Group
Summary of Contents for Proton 206
Page 1: ...PROTON 206 308 System Manual ...
Page 2: ......
Page 3: ...PROTON 206 308 The Smart Communicator System Manual ...
Page 8: ...8 PROTON 206 308 V1 System Manual ...
Page 86: ...86 PROTON 206 308 V1 System Manual ...
Page 92: ...92 PROTON 206 308 V1 System Manual ...
Page 96: ...96 PROTON 206 308 V1 System Manual W Walk In Class of Service 85 X Y Z ...