MSC-XD164S Product Manual
Switch Corporation systems. This value is stored and recalled on power up.
Command
Description
SysName
Query system name.
SysName STR
Set system name (up to 15 characters).
Example for querying and assigning system name
>SysName
MSC-Router
>SysName “MyRouter”
>
3.10.44 SysType Command
Protocol Version: 2.3
NOTE:
Superseded by the
sys.arch
Query the system series type, which is currently defined as one of the following values:
Value Series name
0
Carina
1
Lupus
2
Lynx
3
Hydra
4
Pyxis
NOTE:
This command was not added until version 2.3 of the Mascot protocol. On previous versions, this
command is available on the MSC-GCP2U32 LCD panel but not other Matrix Switch Corporation systems.
When determining the system type, if executing the command returns an Invalid Command error, the system
series can be assumed to be Carina.
Command
Description
SysType
Query the system hardware series.
Examples
>SysType
E01: Invalid command
>SysType
2
>
The first example command shows the response that would be received on a Carina series system with older
firmware not supporting the SysType command, the second example is what might be returned by an MSC-
GCP2U32 LCD panel.
Page 48 of 60
© 2013-2016 Matrix Switch Corporation