MSC-XD0816L Product Manual
FrameIP IP
Set IP address of remote Router system to control (use 0.0.0.0 on Router systems to disable
remote control).
Example to query and assign the remote Router IP
>FrameIP
192.168.2.60
>FrameIP 192.168.2.61
>
3.11.7 Gateway Command
NOTE:
Superseded by the
net.gateway
Query or assign the network Gateway IP address. This is usually only needed on Remote Panel systems which
control a Router device on a different network. This setting is saved and recalled on power up.
Command
Description
Gateway
Query IP address of network Gateway.
Gateway IP
Set IP address of network Gateway.
3.11.8 Get Command
Protocol version 3.0
The Get command is used for querying values of currently Active system parameter values. See the
for a list of currently defined parameters. This command supersedes many individual
configuration commands.
NOTE:
This command queries Active values of parameters which may differ from values in Stored memory.
Values in Stored memory are loaded at system startup and can be queried with the
. See
for more details.
Command
Description
Get
Display all system parameter Active values. Output consists of one parameter per line with
the parameter identifier separated by an equals ‘=’ character and the value.
Get Parameter
Display the Active value of a single parameter or a subset of parameters under a given
parameter node.
Examples of querying all parameters, “mtx” parameters, and “net.ip” parameter.
>Get
ctl.mascot.ver=2.3
ctl.serial.baud=115200
ctl.serial.log=0
ctl.serial.proto=mascot
ctl.serial2.baud=115200
ctl.serial2.log=0
ctl.serial2.proto=mascot
mtx.serial=1
Page 30 of 61
© 2013-2018 Matrix Switch Corporation