SPECIFICATIONS
INSTALLATION
1. Choose a suitable mounting location, ie. Avoid areas subject to heavy shading or interferance by
other light sources eg. Street Lights etc.
WARNING: Before drilling, ensure the area
is clear
of services
eg. Water/Gas pipes, electric cables etc
.
3. Fix unit to wall/ceiling and bring
cable through rear bung
WARNING: Isolate power supply before
commencing wiring
4.
Use the
insulation caps provided, to
cover screw
heads
FSW-12220 HDAD/SUNSET SWITCH
Supply Voltage 240V
±
10%
Frequency
50Hz
Power Consumption
2W
Operating Temperature
-10 to +60°C
Restrictive Maximum Load Rating
20amps
Inductive Maximum Load Rating
3600VA
Fail Safe Position
ON
Lux On/Off
Adjustable:
Time On (hrs)
Adjustable
(via
jumper)
20
200
+
_
6. Once power is applied, lights will come on for a 20sec warm-up period before they are ready for
use.
7. Test by covering lens completely using the box supplied. Please Note: The unit has a built in delay
to avoid nuisance switching and may take up to 20 secs to switch once sunset is stimulated.