DOC:
FPC-12660
VER
2.
2
FUNCTIONAL OVERVIEW
In addition to both audible and visual alarms being activated when a high level occurs, the controller is
designed to provide dishwasher interlock, which immediately isolates power to the Dishwasher, ensuring that
no further 'inflow' to the chamber from the Dishwasher occurs, until the level has subsided.
OPERATION
In the event of ‘high level’, the high level light will
commence flashing, the audible buzzer will
commence sounding and the power outlet, into
which the dishwasher is plugged, will automatically
be switched off.
NOTE:
DO NOT PLUG PUMP INTO THIS POWER
OUTLET
The high level indicator light will remain flashing
until the water level in the chamber has subsided.
The audible buzzer can be muted by way of the
mute button located on the front of the panel.
The power outlet will remain off until the 'high level'
has subsided.
SCHEMATIC
TO SEWER
M A INS WATER
DR
AI
N
DRA IN
M A INS WATER
POWER SUPPLY
TO DISHWASHER
FPC-12660 - WITH DISHWASHER INTERLOCK
UNDERSINK / SULLAGE
CHAMBER ALARMS