MATALA GM-3900 Instruction And Maintenance Manual Download Page 1

-1- 

GeyserMax-Flow Series 

                                                                                                                                           

Waterfall Pump 

 

       

115V/60Hz 

 

GM-3900         

1/5HP 150W / Discharge 1-

1/2”

 

 

GM-4700         

1/3HP 250W / Discharge 2

 

 

GM-5400         

1/2HP 400W / Discharge 2

 

 

GM-6200         

3/4HP 750W / Discharge 2

 

230V/50Hz 

 

GM-3800

         

1/5HP 150W / Discharge 

2” 

 

GM-4700         

1/3HP 25

0W / Discharge 2”

 

 

GM-5300         

1/2HP 4

00W / Discharge 2”

 

 

GM-6200         

3/4HP 75

0W / Discharge 2”

 

 

Instruction and Maintenance Manual 

 

Introduction                                                                                          ___________         

Thank you for selecting the GeyserMax-Flow Series Waterfall Pump. 
 
This instruction manual explains the product operations and gives important precautions 
regarding its safe use. In order to use the product to maximum benefit, be sure to read 
the instructions thoroughly and follow them carefully. 
 
To avoid accident, do not use the pump in any way other than as described in this 
instruction manual especially when you see

 ! WARNING 

. After reading this instruction 

manual, keep it nearby as a reference in case questions arise during use. 
 
If this instruction manual should become lost or damaged, ask your nearest dealer or 

representative for another copy. 

Summary of Contents for GM-3900

Page 1: ...ax Flow Series Waterfall Pump This instruction manual explains the product operations and gives important precautions regarding its safe use In order to use the product to maximum benefit be sure to read the instructions thoroughly and follow them carefully To avoid accident do not use the pump in any way other than as described in this instruction manual especially when you see WARNING After read...

Page 2: ...IL C60 1 19 O RING NBR 1 5 LOWER BEARING COVER FC200 1 20 PACKING NBR 1 6 OIL SEAL COVER NYLON 30 GF 1 21 SCREW SUS304 1 NYLON 30 GF for 22 STRAINER NYLON 30 GF 1 GM3900 GM4700 23 PUMP FEET SHEATH NBR 1 SUS430 PU for 24 WASHER SUS304 1 GM5400 GM6200 25 WASHER SUS304 1 8 UPPER PUMP CASING NYLON 30 GF 1 26 NUT SUS304 1 9 LOWER PUMP CASING PP 30 GF 1 27 KEY SUS304 1 10 CAPACITOR 1 28 SCREW SUS304 8 1...

Page 3: ...se of your pump Other specifications are noted in the chart below Dimension Weight Hp W Inch mm Head Ft M Flow GPH LPH Head Ft M Flow GPH LPH L x W x H Inch mm lb kg GM 3900 1 5 150 1 1 2 38 11 5 2026GPH 22 5 3900GPH 9 4x6 5x14 240 165 355mm 15 4 7 GM 4700 1 3 250 2 50 13 3480GPH 27 5 4700GPH 9 4x6 5x14 240 165 355mm 15 4 7 GM 5400 1 2 400 2 50 16 3600GPH 32 8 5400GPH 9 4x6 5x14 8 240 165 375mm 17...

Page 4: ...equipment out of the reach of children Warns that the failure to follow the directions given could cause serious risk to individuals or objects WARING This sign warns the operator that the failure to follow an instruction may damage the pump and or the system WARNING ...

Page 5: ...o not connect pump to a power supply until permanently grounded For maximum safety connect pump to a circuit equipped with a Ground Fault Circuit Interrupter device when you position the pump s grounding wire 5 Voltage of power supply must match the voltage of the pump 6 Before installing pump clear sump basin of any water debris or sediment WARNING Sump basin must be vented in accordance with loc...

Page 6: ...curred by any customer in removing and or reaffixing any Matala Pump product parts or component THE WARRANTY WILL NOT APPLY a to defects or malfunctions resulting from failure to properly install operate or maintain the unit in accordance with printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and the parts used in connection wi...

Page 7: ...reely in basin Defective float switch Replace with float switch Defective vertical switch Replace with vertical switch Pump runs but delivers only a small amount of water Pump is air locked Start and stop several times by plugging and unplugging cord Check for clogged vent hole in pump case Vertical pumping distance is too high or pipe size is too small Reduce vertical distance or increase the pip...