MLI Ultra 12/1250, 24/1250
– User and Installation Manual
13
5. CONFIGURATION
Out of the box, the MLI Ultra is suitable for use in a MasterBus network or as a stand-alone battery. For
CZone and for advanced features, the settings must be adjusted. Most settings can be done through
DIP switches. Advanced or network settings are done from a Windows laptop or notebook with either
the free MasterAdjust or the CZone configuration tool. MasterAdjust software can be downloaded at
www.mastervolt.com. The CZone Configuration Tool software is available to technical CZone
customers from the CZone Portal.
DIP switch settings
By default, all DIP switches are off.
MasterBus DIP switch settings
1. Set DIP switch 1
ON
(1).
2. Set DIP switches 2 to 8 to fit your needs. DIP switches 9 and 10 are not used in MasterBus.
DIP switch 2 3 4 5 6 7 8
MasterBus Powering off
MasterBus Powering on
0
1
Event-based 'stop charge' can be setup per charger
Automatic 'stop charge' for ALL Mastervolt chargers
(see section "Stop Charge event" on page 18)
0
1
Cluster setting for multi-unit configuration:
Stand-alone
Replica unit
Primary 12V unit
Primary 24V unit
Primary 36V unit
Primary 48V unit
(see section "Configuration of a battery bank
0
0
0
0
1
1
0
0
1
1
0
0
0
1
0
1
0
1
Auto switch-on enabled
Auto switch-on disabled
0
1
Battery detect disabled
Battery detect enabled
0
1
Battery detect: If the battery is switched-off, there will be no voltage at the poles and some chargers will
not start charging. By enabling the Battery detect option, this is fixed. Note that if a load is connected
that this will slowly drain the battery (5-10mA).
CZone DIP switch settings
1. Set DIP switch 1 to the
OFF
position (0).
2. Set DIP switch 2 to the
OFF
position (0).
3. Set DIP switches 3 to 10 to match the unique 'dipswitch' number, used in the CZone network.
How to change the DIP switch settings
Figure 9: DIP switches