21

 

 

 

 

 

6.6 

EasyView 5 configuration settings 

To enable configuration: 
1.  Tap the settings button. 

2.  Tap Configuration, enter Pin code 1991 and tap the confirm button in the top right corner. 

3.  Go to the configuration tab. 
The EasyView 5 configuration menu is used for read out and adjustment of settings. 

Item 

Meaning 

Default 

Range 

General 

 

 

 

System name 

Name of the system the EasyView 5 is 

installed on. 

System 

name 

Maximum 16 

characters 

Device name 

Name of this device. This name will be 

recognized by all connected devices. 

DIS 

EasyView 5 

DIS+Maximum 12 

characters 

Switch X 

Switches to use for event configuration. 

Renaming the switches after their 

application is recommended. X ranges 

1 – 6. 

Switch X 

Maximum 16 

characters 

Devices in list 

Devices to show in the device list. At 

Selection

 five selection boxes appear to 

choose a MasterBus device connected. 

Excluded

 means, you can select all 

devices except a maximum of five 

excluded devices. 

 

Selection, All, 

Excluded 

Auto Lock after 

Time after which to lock the panel. 

Off 

Off, 2, 5, 10 minutes  

Alarm 

To only show alarms of selected 

devices, select 

selection

All 

All, selection 

Show edit b. 

 Show the Edit widgets button. 
 Hide the Edit widgets button. 

You may want to hide this button to 

prevent accidental removal of widgets. 

Shown 

Shown / hidden 

Message 

 

 

 

Message X 

Title of custom alarm message. X 

ranges 1 – 6. See section 6.11. 

 

Maximum 16 

characters 

Message text X 

Additional line(s) for alarm message X. 

 

Maximum 16 

characters 

Events 

 

 

 

Event X Source 

See section 6.7. 

Event X Target 
Event X Command 
Event X Data 

 

Summary of Contents for EasyView 5

Page 1: ...n anderen Sprachen herunterzuladen besuchen Sie bitte unsere Website Pour t l charger ce manuel dans d autres langues consultez notre site Web Para descargar este manual en otros idiomas visite nuestr...

Page 2: ...12 5 2 1 Switching on off or standby 12 5 2 2 Locking 12 5 2 3 Home 12 5 3 Dashboard and navigation 13 5 4 Maintenance 13 6 Monitoring and configuration 14 6 1 Favorite pages 14 6 1 1 Adding widgets t...

Page 3: ...gure and operate all connected devices in a MasterBus network 1 1 Parts Parts 1 Front cover 2 Display panel 3 Top cover 4 Seal 5 Wall box 6 Bottom cover Always use the front cover when the EasyView 5...

Page 4: ...4 EasyView 5 User and Installation Manual 1 2 Connections Connections 1 MasterBus port 1 2 MasterBus port 2 3 USB device port 4 Power input 12 24 V...

Page 5: ...d Installation Manual 5 1 3 Accessories Accessories 1 Mastervolt EasyView 5 2 MasterBus cable 6 meter 20ft 3 MasterBus terminator 4 12 24 V connector 5 Mounting screw 4 pcs 4x30mm PH2 6 Mounting screw...

Page 6: ...nder performance damage or failure of the product and may void this warranty The warranty is limited to the cost of repair and or replacement of the product Costs for labor or shipping are not covered...

Page 7: ...Every device that is compatible with MasterBus is equipped with two data ports The devices are simply chained together forming a local data network Monitoring panels such as the EasyView 5 can be use...

Page 8: ...evices can be connected together MasterBus needs a terminating device on both ends of the network The electric power for the network comes from the connected devices At least one device in the network...

Page 9: ...ions The EasyView 5 offers three mounting options Panel mounting onto the wall box see section 4 1 Flush mounting in an 82 x 113 mm hole see separate instruction sheet with saw template Clamp mounting...

Page 10: ...the mounting hole are too big the wall box can also be used as a mounting clamp Position the wall box at the back side of the installation panel and use the supplied screws to fasten the display onto...

Page 11: ...see section 1 3 4 3 1 Aux power connector Connect the positive wire to the left terminal the negative wire to the right terminal of the connector Use a 3mm flat blade screw driver to tighten the scre...

Page 12: ...long press i e press and hold the button for about 3 seconds the Home button and tap the Off option in the menu that appears To switch to standby mode long press the Home button and tap the Standby op...

Page 13: ...n Opens the list of active alerts The button is only present when an alert is active USB button Opens the USB update page The button is only present when an USB flash drive is detected Edit button Ope...

Page 14: ...ring your favorite page s This button may be hidden See section 6 6 After tapping the Edit button you enter the Edit page To go back to the dashboard tap the back arrow Tap the plus button to add widg...

Page 15: ...n of more items is automatically blocked In total 6 favorite pages can be configured Upon return to the Edit page the selected items appear as widgets An empty bullet is shown at the bottom of the Edi...

Page 16: ...on 6 6 2 Long press the widget you want to move Arrow buttons will appear 3 Move the widget to the required position by tapping the arrow button s 4 When finished first tap the red cross in the top ri...

Page 17: ...button to go to the Edit page This button may be hidden See section 6 6 Tap the widget name to open the Custom name page Make the required change and tap the confirm button Note the customized name w...

Page 18: ...s from the list with an active alarm are accompanied by an alarm symbol 6 3 Device page From the System screen section 6 2 tap on a device to go to the Device page Each device has its own Device page...

Page 19: ...buzzer can sound even if you switched it off in the configuration See section 6 7 You can also create your own alarm messages These alarms have a yellow border See section 6 11 In case an alarm is pr...

Page 20: ...target in the MasterBus events See section 6 7 This means the buzzer can sound even if you switched it off in the configuration On On Off Configuration Enter Pin code to unlock the configuration menu...

Page 21: ...ication is recommended X ranges 1 6 Switch X Maximum 16 characters Devices in list Devices to show in the device list At Selection five selection boxes appear to choose a MasterBus device connected Ex...

Page 22: ...ice to take action due to Event X Choose System dependent Event X Command Event based command Action to be taken by the Event X target Choose System dependent Event X Data Event 1 data controls the Ev...

Page 23: ...Copy lets the status follow the input Copy Invert lets the status follow the opposite of the input Copy is used for dimming too by holding the pulse switch pressed for a longer time Toggle changes th...

Page 24: ...p the confirmation button in the top right corner 6 When all required text lines are entered tap the left arrow button in the top left corner of the screen twice to go to the System page 7 Tap the dev...

Page 25: ...ted and a USB flash drive button appears on the dashboard After the EasyView 5 has been switched off and on the USB button is being shown in the left upper corner of the screen Tap the USB button to g...

Page 26: ...instrument to retrieve historical data of your electrical installation 9 Trouble shooting Contact your local Mastervolt Service Centre if you cannot correct a problem with the aid of the trouble shoo...

Page 27: ...s of the network Check if connected see section 3 3 MasterBus network is configured as a ring network Ring networks are not allowed Check the connections of the network see section 3 3 T connections i...

Page 28: ...me see section 6 6 Wrong language is displayed Wrong setting of the language at the EasyView 5 See section 6 5 for adjustment of the language Wrong setting of the language at one of the connected devi...

Page 29: ...36kg 0 79lbs Dimensions 113 x 127 x 43 mm 4 4 x 5 0 x 1 7 inch Display size 109 mm 4 3 inch Display languages EN NL DE ES IT FR FI SV NO DA RU IP degree IP67 front IP23 back Power supply MasterBus 12V...

Page 30: ...30 EasyView 5 User and Installation Manual 70 97 3 4x Front mounting holes 127 113 82 113 Front Back without wall box...

Page 31: ...EasyView 5 User and Installation Manual 31 43 Case partly removed to show mounting hole details 40 7 9 5 2 Side with wall box Side without wall box...

Page 32: ...rvolt com Location Shipping Power Products LLC N85 W12545 Westbrook Crossing Menomonee Falls Wisconsin 53051 United States Asia Pacific Customer Service T 64 9 415 7261 Option 1 E enquiries bepmarine...

Reviews: