98063-BT DIGITAL VACUUM GAUGE with Bluetooth
®
Wireless Technology
INSTRUCTION MANUAL
ENTER
ALARM
UNITS
Micron
Torr
mTorr
mmHg
mBar
Pa
FEATURES:
• Sintered bronze inlet filter to protect the sensor
• 5-digit LCD screen features an ultra-vibrant blue back-light allowing for easy readability
• Chemical resistant sensor for ease of cleaning
• Low battery icon displayed on the LCD indicates that the batteries are low and need to be
replaced
• Calibration can be performed while in the field environment
• Audio and visual alarm when vacuum goes below a user adjustable set point
• Bluetooth
®
wireless technology provides communication to hand-held smart devices through
the Mastercool Connect app
SPECIFICATIONS:
• Sensor: Glass bead thermistor with temperature compensation
• Connection Fitting: 1/4 SAE F-FL with stem depressor
• Operating Temperature: 32 to 120˚F (0 to 45˚C)
• Vacuum Units: Micron, Torr, mTorr, mmHg, mBar, Pa
• Range: 20,000 to 1 micron
• Accuracy: ±10% of reading (from 10,000 to 100 microns)
• Proof Pressure: 450 psi
• Auto-Off: Automatic after 10 minutes, blue backlight after 3 minutes
• Power: 2 AA batteries included
• Battery Life: 100+ continuous hours (depending on backlight use)
• Weight: 0.3 lb (0.13 kg) without batteries / 0.5 lb (0.23 kg) with batteries
• Dimensions: 1.9” x 6.3” x 1.4” (50 mm x 160 mm x 36 mm)
Specifications for Bluetooth
®
wireless technology:
• 260’ (80m) maximum line-of-sight range
• Bluetooth
®
4.2 and 5
WARNINGS
Wear Safety Glasses. Wear Gloves
Keep in a dry place. Do not allow moisture to enter the unit.
WARNING:
This product can expose you to chemicals including lead and lead compounds,
which are known to the State of California to cause cancer and birth defects or other
reproductive harm. For more information go to www.P65Warnings.ca.gov.
REPLACEABLE PARTS
42010
Replacement gasket for 1/4” fitting
42014
Replacement depressor for 1/4” fitting
99333
1/4 FL-M x 1/4 FL-M x 1/4 FL-F tee (optional)
BATTERY INSTALLATION
Slide to remove the battery compartment cover. Make sure to place the batteries into the
compartment with the correct polarity. Replace battery cover.
BASIC SET-UP
• POWER
Press the button to turn the unit on. The vacuum gauge’s display will count down during
warm-up, then the vacuum will be displayed. Above 20,000 microns, dashes will be displayed.
• UNITS
Press the UNITS button once to enter unit mode. Use the UNITS button to scroll through the
units until desired selection is displayed. To save the selected unit and return to sensing
vacuum, press the ENTER button.
• VACUUM LEVEL ALARM
The alarm indicates when the vacuum has dropped below a set value. Press ALARM once to
display the current setting. Use the
and
arrows to adjust the alarm setting. Press ENTER
to save the new setting. To acknowledge the alarm and silence it, press any button. To keep
the alarm from engaging, set the alarm to 0.
• BACKLIGHT
The backlight will turn on when the unit turns on. The backlight will automatically turn off
after 3 minutes. To turn the backlight back on, press any key.
• AUTO OFF
The vacuum gauge will turn off after 10 minutes at atmospheric pressure. The vacuum gauge
will not turn off at deep vacuum or if Bluetooth
®
is connected.