14. Appendix A
– Turning the Filter Head Assembly (FHA)
The following steps describe removing and turning the FHA in order to orient the system in a
non-standard configuration. Reference
Orientations 3 & 4
– Reversed Filter Head Right and
Left
on page
1. Raise the filter motor at least 8 cm from its
bottom stop position or to the memorized 3D
position.
2. Power off and unplug the MI-CLARITY3D.
3. Loosen and remove the four hex-head bolts
attaching the motor mount to the support
bracket, while supporting the weight of the
filter head assembly.
4. Remove the FHA.
5. Turn around the head assembly through
180° taking care not to stress the control
cables. Place the mounting bracket on the rubber pad and reattach the motor
mount with the four hex-head bolts.
6. Confirm that the PFD faces the correct direction when positioned in front of the lens
– polarizing filter material to the screen side of the filter disk. Change the PFD
direction if necessary.
IMPORTANT:
PFD Home Position adjustment is required
. Refer to section 8.7,
Setting the PFD Home Position, on page 35.
Use hex key to remove bolts