background image

 

15

MASTER-BILT PART NUMBERS 

 
The table below gives Master-Bilt part numbers.  Use this chart when ordering replacement parts for your 

TAF

  

ERC2 cases. 
Description 

TAF-27 TAF-48 TAF-74 

Bulb 

23-00343 

23-00343 

23-00343 

Bulb 

Holder 

23-01080 23-01080 23-01080 

Bulb Shield 

23-01465 

23-01465 

23-01465 

Caster W \ Brake 

27-00591 

27-00591 

27-00591 

Casters W \ O Brake 

27-00590 

27-00590 

27-00590 

Coil Defrost Heater 

17-00443 

17-09113 

17-09076 

Condensate Heater 

17-00421 

17-00421 

17-00421 

Condensing 

Unit 

01-01488 01-01510 01-01487 

Controller Kit

*

 

19-13761 

19-13761 

19-13761 

       10’ Cable  

19-13760 

19-13760 

19-13760 

       Controller Display 

19-13756 

19-13756 

19-13756 

       T-Sensor (2) 

19-13758 

19-13758 

19-13758 

Door Frame Heater 

17-09449 

17-09142 

17-09142 

Door 

Gasket 

37-01207 37-01211 37-01211 

Door Handle 

35-01488 

35-01488 

35-01488 

Door Hinge Assembly 

A35-01501 

A35-01501 

A35-01501 

Door Light Switch 

35-01506 

35-01506 

35-01506 

Door Opening Trim 

29-01481 

29-01481 

29-01481 

Drain Line Heater 

17-00404 

17-00404 

17-00404 

Drier 

09-09171 09-09506 09-09506 

Evaporator Coil 

07-00750 

07-13089 

07-13089 

Evaporator Fan Blade 

15-01184 

15-01184 

15-01184 

Evaporator Fan Guard 

25-00205 

25-00205 

25-00205 

Evaporator Fan Motor 

13-00685 

13-00685 

13-00685 

Expansion Valve 

09-09187 

09-09542 

09-09542 

Female Plug 

21-00577 

 

 

Heater Safety Control 

19-01307 

19-01164 

19-01164 

Leg 

27-00558 27-00558 27-00558 

Pilaster 

33-01408 

33-01408 

33-01408 

Pressure Control 

 

19-13173 

19-13173 

Power Cord 

21-01454 

21-01454 

 

Shelf 

Clips 

33-01011 33-01011 33-01011 

Shelves 

33-01455 

33-01456 

33-01456 

*

The control kit has an optional Alarm Transformer for 115 volts (part #19-13190), 230 volts (part #19-13190), 

and Buzzer (part# 19-13759) 

 
 
 
 
 
 
 
 
 

Summary of Contents for TAF-27 ERC2 s

Page 1: ...Installation Operations Manual Master Bilt Products 908 Highway 15 North New Albany MS 38652 Phone 800 684 8988 PN 228 90000 Rev 05 04 04 bhs...

Page 2: ...2...

Page 3: ...TRUCTIONS 6 Inspection for ShippingDamage 6 INSTALLATION INSTRUCTIONS 6 General Instructions 6 Electrical 6 Leg and Condensate Pan Installation 7 ELECTRONIC REFRIGERATION CONTROL ERC 8 FINAL CHECK LIS...

Page 4: ...If this case is to be located against a wall there should be at least 6 space between the wall and the back of the case see page 7 This space will allow for the circulation of air behind the case whi...

Page 5: ...ing signal words are used in the warnings and safety messages DANGER Severe injury or death will occur if you ignore the message WARNING Severe injury or death can occur if you ignore the message CAUT...

Page 6: ...if the cabinet is malfunctioning or if there is a drainpipe leaking MECHANICAL Remove front grille and check refrigeration lines to see that they are free not touching each other or compressor Spin co...

Page 7: ...temperatures for short periods of time 6 When replacing burned out fluorescent tubes be sure that the electrical power to the lighting circuit is turned off ELECTRICAL WARNING Before servicing electr...

Page 8: ...s The TAF 27 models are cord connected and operate on a 15 amp 115 60 1 circuit The TAF 48 and TAF 74 models have two junction boxes mounted on top of the cabinet at the right rear for permanent conne...

Page 9: ...T to accept the new time Step 5 Press DOWN to go to the next parameter Set point Temperature cut out Step 6 Press SET to change the set point temperature Step 7 or Press UP or DOWN to go to the desire...

Page 10: ...Status dSPL Information shown on the display during operation conditions tdAy time of day rSP zone temperature CyCL cycle between time and zone temperature Epr evaporator coil temperature rSP Clock Fo...

Page 11: ...e Range from 0 to 15 min 2 for LT 0 for MT Pump Down Pudn Pump down duration Range from 0 to 59 min 0 min Drip Time driP Drip time duration Range from 0 to 59 min 2 for LT 0 for MT Setpoint Differenti...

Page 12: ...on the display Press SET to accept the change Press DOWN to go to Defrost Start Time dEF1 Press SET to change the time Press UP or DOWN until the 11 59 PM appears on the display Press SET Press DOWN...

Page 13: ...s in the probe the control has LED functions as a diagnostic tool When power is supplied to the control the LED will turn on and will remain on as long as this condition is satisfied When there is a f...

Page 14: ...Compressor starts and runs but cycles on overload A Low voltage B Dropped phase 3 phase C Overload protector defective D High head pressure see 1 6 Compressor will not start hums but cycles on overloa...

Page 15: ...Gasket 37 01207 37 01211 37 01211 Door Handle 35 01488 35 01488 35 01488 Door Hinge Assembly A35 01501 A35 01501 A35 01501 Door Light Switch 35 01506 35 01506 35 01506 Door Opening Trim 29 01481 29 01...

Page 16: ...ster Bilt at 800 684 8988 The customer service department at Master Bilt should be contacted at the time of sale or disposal of your cabinet so records may be kept of its new location If you sell or g...

Page 17: ...17...

Page 18: ...18...

Reviews: