background image

6/17 Rev.  D  57-02400 

 

 

 

       

 

 

 

         

  

 

 

  

  

  

 

 

Installation & Operations Manual for 

 

 

 

 

MBGFP-HG Model 

Bottom Mounted Swing Glass Door 

Freezer Merchandisers With Lighted Sign 

 
 
 

Summary of Contents for BLG-23-HGP

Page 1: ...6 17 Rev D 57 02400 Installation Operations Manual for MBGFP HG Model Bottom Mounted Swing Glass Door Freezer Merchandisers With Lighted Sign...

Page 2: ...6 17 Rev D 57 02400 2 Customer Service Warranty Parts Phone 800 684 8988 Fax 866 882 7629 Email service master bilt com...

Page 3: ...ICAL 6 ELECTRICAL 7 Leg Caster Installation 7 DOORS 8 Grill 9 ELECTRONIC REFRIGERATION CONTROL 10 Programming5555555555555555555555555555555555555555510 List of Parameters55555555555555555555555555555...

Page 4: ...s space will allow for the circulation of air behind the case which will prevent condensation on the exterior surfaces NOTICE Read this manual before installing your cabinet Keep the manual and refer...

Page 5: ...warnings and safety messages DANGER Severe injury or death will occur if you ignore the message WARNING Severe injury or death can occur if you ignore the message CAUTION Minor injury or damage to you...

Page 6: ...ssible exposing only small quantities to store temperatures for short periods of time 6 When replacing burned out light bars be sure that the electrical power to the lighting circuit is turned off NOT...

Page 7: ...it drops below 207 when the compressor tries to start it is an indication of too small supply wiring or too long to run It is recommended that a separate circuit be run for each cabinet to prevent an...

Page 8: ...other mechanical device to remove foreign residue or objects directly from the coated glass Do not use abrasive cleaners or materials on the coated glass Examples of these cleaners or materials inclu...

Page 9: ...6 17 Rev D 57 02400 9 GRILL To remove bottom grill unscrew the 2 screws on the bottom for the grill then drop the grill down from the key slot hole and pull out See Figure 4 Figure 4 Screw Screw...

Page 10: ...nd the 2 minute drip time has passed There is 2 minutes delay after a defrost before the fan comes on If the Evaporator temperature is 35 o F or below the controller will override the fan delay FAN LE...

Page 11: ...15120min 30min ELECTRICAL CONNECTIONS The controller is provided with a screw terminal block to connect cables with a cross section up to 2 5 mm 2 Before connecting cables make sure the power supply c...

Page 12: ...on at the Torque Adjustment SERVICE INSTRUCTION 1 High head pressure and high back pressure A Condenser coil clogged or restricted B Condenser fan motor defective C Air discharge in rear of cabinet re...

Page 13: ...w sensor in the original position Use plastic tie to tighten the zone sensor Insert the sensor for defrost termination firmly into top center of the evaporator coil in between the fins Make sure the s...

Page 14: ...7 09568 17 09569 17 09570 Drain Line Heater 17 00404 17 00404 17 00404 17 00404 Defrost Heater Safety 19 01164 19 01164 19 01164 19 01164 Compressor 03 15192 03 15192 03 14902 03 14898 Condenser Coil...

Page 15: ...de them free Contact the customer service department at 800 684 8988 The customer service department should be contacted at the time of sale or disposal of your cabinet so records may be kept of its n...

Page 16: ...6 17 Rev D 57 02400 16...

Page 17: ...6 17 Rev D 57 02400 17...