Masport F38-LPG1 Owners & Installation Download Page 1

06/03/04

Freestanding Gas Stove

FOR YOUR SAFETY
What to do if you smell gas:

Do not try to light any appli-
ance
Do not touch any electrical
switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you  cannot reach your
gas supplier, call the fire
department.

WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional infor-
mation consult an authorized installer, serv-
ice agency or the gas supplier.

FOR YOUR SAFETY
Do not store or use gasoline or other flamma-
ble vapours and liquids in the vicinity of this
or any other appliance.

Installation and service must be performed
by an authorized installer, service agency or
the gas supplier.

PLEASE KEEP THESE INSTRUCTIONS

FOR FUTURE REFERENCE

Owners &
Installation

Manual

LISTINGS AND CODE APPROVALS

These gas appliances have been
tested in accordance with AG 103,
NZS 5262 and have been certified by
the Australian Gas Association for
installation and operation as
described in these Installation and
Operating Instructions.

Your unit should be serviced
annually by an authorised service
person.

918-186b

Models: F38-NG1

F38-LPG1

Australia
P.O. Box 533
Braeside, Victoria   3195

New Zealand
1-37 Mt  Wellington Hwy.Panmure,
P.O. Box 14349
Auckland 6.

Summary of Contents for F38-LPG1

Page 1: ...lier FORYOURSAFETY Donotstoreorusegasolineorotherflamma ble vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorized installer ser...

Page 2: ...rovide you with all the warmth and charm of a woodstove at the flick of a switch The models F38 NG1 and F38 LPG1 of this series has been approved by AGA for both safety and efficiency Asitalsobearsour...

Page 3: ...Glass Gasket 17 GlassReplacement 17 FanMaintenance 18 RemovingValve 19 DC Spark Box Battery Replacement 19 Parts List 20 Warranty Warranty 23 Safety Label Specifications 2 SafetyLabel 4 Installation...

Page 4: ...e We have print ed a copy of the contents here for your review The safety label is located on the inside of the drop down pedestal door NOTE Masport units are constantly being im proved Check the labe...

Page 5: ...ANCE BE KEPT CLEAN DUE TO HIGH TEMPERA TURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES THISAPPLIANCECANONLY BEFLUEDINACCORDANCE WITH AG 601 OR LOCAL CODES F...

Page 6: ...appliance and must be connected to a chimney flue in accordance with the installation codes Note The rear pedestal cover plate must always be fitted for safety Electri cal connections inside For your...

Page 7: ...en the IN 7 and or OUT 6 pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pressure tap s using a 5 16 ID hose 4 Light the pilot and turn the...

Page 8: ...emove and discard the 3 pressure regu lator mounting screws A pressure reg ulator tower B and diaphragm C 5 Insure that the rubber gasket D is properly positioned and install the new HI LO pres sure r...

Page 9: ...inkle the embers on the left and right sides of the firebox base LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams If logs are broken do not use the unit until they...

Page 10: ...ion check that area for any block age of the burner port F 0 2 4 7 E 02 45 A 02 65 G 02 48 D 0 2 4 6 B 02 56 C 02 44 Cutout Pin D 02 46 B 02 56 A 02 65 6 Place the Left Top Log D 02 46 on the pin on L...

Page 11: ...draft INSTALLATION Diagram 1 FRONT DOOR INSTALLATION 1 Open the two side panels 2 Slide the door onto the two hinge pins making sure the two pieces are flush to gether See diagram 1 4 The latches shou...

Page 12: ...auses sooting or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer CAUTION Do not connect the millivolt remote control wires to the 240V wires 3 Inst...

Page 13: ...thathree pronged grounding plugforyourpro tection against shock hazard and shouldbepluggeddirectlyintoaprop erlygroundedthree prongreceptacle Do not cut or remove the grounding prong from this plug No...

Page 14: ...ble shock 3 Check to ensure there are no gas leaks 4 Make sure the three pieces of door glass are properly positioned Never operate the appliance with any of the glass removed or with the door open 5...

Page 15: ...supplier a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service te...

Page 16: ...changes within the unit these sounds will likely re occur Again this is normal for steel fireboxes Blower Thermodisc When this thermally activated switch turns ON it will create a small clicking soun...

Page 17: ...he pilot or burner ports 5 Keep the area near the appliance clear and free from combustible materials gasoline and other flammable vapours and liquids 6 Verify proper operation after servicing LOG REP...

Page 18: ...uld be plugged directly into a properly grounded three prong re ceptacle Do not cut or remove the grounding prong from this plug To Remove F38 1 Fan 1 Unplug or disconnect power source to stove 2 Remo...

Page 19: ...it doesn t get marked up See diagram below 5 Carefully remove the logs and lava rock 6 At this point you should disconnect the gas at the valve 7 Remove the burner by removing the two 1 4 hex head sc...

Page 20: ...6 518 Side Panel Door Assy Right Side 20 756 520 Side Panel Door Assy Left Side 21 560 031 560242 Hinge for Side Panel 23 904 258 551891 Side Panel Door Magnet Part Aust New Zealand Description Aust N...

Page 21: ...LPG 904 689 33 Orifice NG at 38 mj 904 390 52 Orifice LPG at 31 mj 910 074 Spark Generator Switch c w Wire 71 752 528 Rear Log Bracket Assy 72 910 034 Pilot Assy S I T 3 flame NG 910 035 Pilot Assy S...

Page 22: ...932 Gold Wrap Door Complete 730 928 Gold Panel Door Complete 101 650 920 Door Gasket Kit 105 Ceramic Paper 106 940 323 P Side Glass 107 936 243 Glass Gasket 108 940 322 P Centre Glass 111 Door Frame...

Page 23: ...ed Masport Service Agent This Express Warranty Does Not Cover 1 Defects malfunctions or failures caused by incorrect installation normal wear and tear misuse neglect acci dental damage or failure to f...

Page 24: ...Printed in Canada Copyright 2005 FPI Fireplace Products International Ltd All rights reserved...

Reviews: