Marvel MPCP415 Owner'S Manual Download Page 1

OWNERS GUIDE

MARVEL PROFESSIONAL UNDERCOUNTER REFRIGERATION

T H E   O R I G I N A L   R E F R I G E R A T I O N   E X P E R T S   S I N C E   1 8 9 2

F O R   M O D E L   #   M P B V 4 1 5

OWNER’S GUIDE

M A RV E L   P R O F E S S I O N A L   U N D E R C O U NT E R   R E F R I G E R AT I O N 

T H E   O R I G I N A L   R E F R I G E R AT I O N   E X P E RT S   S I N C E   1 8 9 2

FOR MODEL # MPCP415

Summary of Contents for MPCP415

Page 1: ...RATION T H E O R I G I N A L R E F R I G E R A T I O N E X P E R T S S I N C E 1 8 9 2 F O R M O D E L M P B V 4 1 5 OWNER S GUIDE MARVEL PROFESSIONAL UNDERCOUNTER REFRIGERATION THE OR I GI N AL RE F...

Page 2: ...e and social media Bonus Third Year Warranty Free with Product Registration Your Marvel Professional product qualifies for a one year extension of the two year warranty coverage from your date of purc...

Page 3: ...sal Integrated Panel Dimensions Integrated Panel Installation Installing The Water Supply Installing the Drain plumbing Maintenance Care and Cleaning Long Term Storage Winterization Operating Instruct...

Page 4: ...em free installation and operation IMPORTANT SAFETY INSTRUCTIONS WARNING WARNING You can be killed or seriously injured if you do not follow these instructions WARNING State of California Proposition...

Page 5: ...in ternal components in place The owners manual is shipped inside the product in a plastic bag along with the warranty registration card and other accessory items Important Keep your carton and packag...

Page 6: ...d Fault Circuit Interrupters GFCI are prone to nui sance tripping which will cause the appliance to shut down GFCI s are generally not used on circuits with power equip ment that must run unattended f...

Page 7: ...power outlet into the rear wall to gain the thickness of the power cord plug Not all recessed outlet boxes will work for this applica tion as they are too narrow but a recessed outlet box equivalent...

Page 8: ...ht Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is correctly positioned...

Page 9: ...can be opened individually one at a time without interference Figure 10 However to ensure unobstructed door swing opening both doors at the same time 1 4 6 4 mm of space needs to be maintained betwee...

Page 10: ...of door Figure 16 Figure 17 Figure 18 4 Remove caps from top of door Using a Philips Screwdriver install magnet actuator on opposite side Install caps into opposite side 5 Remove caps from screw hole...

Page 11: ...d Door 15 38 1 cm wide appliance Right Hand Hinged Door 15 38 1 cm wide appliance Clearance for hinge at top and bottom Hinge side of door Top of door Left Hand Hinged Door 15 38 1 cm wide appliance L...

Page 12: ...Integrated panel models are designed for use with built in installations only Use in freestanding instal lations could result in personal injury If you purchased an integrated panel model your unit is...

Page 13: ...g at a corner of the door remove the magnetic door gasket from the interior side of the door see Figure 25 Set the gasket aside on a flat surface There are 10 holes in the gasket retainer extrusions 3...

Page 14: ...oor and centered along the width of the door See Figure 24a Drill holes through the gasket extrusion using the 10 holes as pilot holes Use the drill size from the chart in Table A being careful not to...

Page 15: ...e cabinet Z bracket INTEGRATED DOOR PANEL INSTALLATION Figure 27 Step 6 Install lock cam Attach the lock cam to the back of the lock assembly with the phillips head screw provided Orient the lock cam...

Page 16: ...Cleaning section Showroom Mode Hold and for 5 seconds The F V PERO ZLOO DVK LVSOD ZLOO EH OLW DQG LQWHULRU OLJKW will function Unit will not cool Repeat command to return to normal operation Electron...

Page 17: ...U the door is closed and standard bright white when the door is open See Control Operations sections for details and other options For more information about BrightShield visit www marvelrefrigeration...

Page 18: ...to be pulled out from the installation for servicing or cleaning Connect the copper tubing to the top side of a cold water pipe to prevent the ice maker from plugging with sediment ease servicing the...

Page 19: ...opriate drain and cut to length Optional Drain Pump An optional drain pump is available if you have purchased an ice machine without one and do not have access to a gravity drain Installation instruct...

Page 20: ...tion instructions to determine the proper amount of cleaning solution to add based on evaporator plate Pour the cleaning the fresh water reservoir Splash shield brackets Pour cleaning solution slowly...

Page 21: ...ent All models use LED lamps to illuminate the interior of the of the LED CAUTION Energy Saving Tips The following suggestions will minimize the cost of operating your ice machine appliance 1 sources...

Page 22: ...ne must have all water drained and removed to prevent ice machine damage as well as possible water damage to the surrounding area in freezing conditions These damages are not covered under warranty Do...

Page 23: ...to the reservoir and drain the remaining water left in the water line trap area To disconnect the water outlet line Push up on the white collar and pull the plastic water line from the bottom of the w...

Page 24: ...the power cord to a wall outlet and turn the water leaks storage bin The drain pump should activate and discharge water Check for water leaks at all hose connections access for the air hose Apply air...

Page 25: ...rt section In all correspondence regarding service be sure to give the service number serial number and proof of purchase Try to have information or description of nature of the problem how long the a...

Page 26: ...hold refrigerator This subject is discussed on page Do you hear water being circulated in the ice machine This is a normal sound as water is added once every ice making cycle Is there a whoosing sound...

Page 27: ...ributor tube restricted Check the water line to the ice machine to make sure there are no restrictions Troubleshooting the Drain Pump If the drain pump reservoir not the ice machine bin If the ice mac...

Page 28: ...in question The part that caused the damage must be returned to Marvel in its entirety The part must be clearly labeled with the serial number of the unit it was removed from the date and the service...

Page 29: ...y labor 2021 04 23 050H 1 I I I Year Warranty Claims Day Factory use Only Units must be registered prior to warranty submittal Customers may register at www marvelrefrigeration com A proof of purchase...

Page 30: ...er and part description Some parts will require color or voltage information Marvel requires the return of original parts we will inform you when the parts order is taken This requirement will be note...

Page 31: ...Of PROPERTY IN ACCORDANCE WITH FEDERAL OR LOCAL REGULATIONS FLAHHABLE REFRIGERANT USED R 600A Specifications Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when...

Page 32: ...ended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the system prior to brazing any part of the sealed system Only a clean dry leak free system should...

Page 33: ...uate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required R 600A Specifications When re brazing the system must be purged with dry nitrogen and at least one ac...

Page 34: ...microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two minutes to clear the charging hoses Seal the Schrader Type access port a proper cap and seal...

Page 35: ...um temperature temperature cool cool No Gas 0 PSIG to 25 Room Cool to hot temperature cool System Diagnosis Guide Condenser Capillary Evaporator Wattage Tube Very hot Warm Cold Normal Hot to warm Cool...

Page 36: ...aces you touch are not hot or frozen Do not touch a bare circuit board unless you are wearing an anti static wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit...

Page 37: ...39 HWC524 2A 40 HWC336 1A 41 HBD324 1A 42 HBD324 2A 43 HBD524 1A 44 HBD524 2A 45 HWD324 2A 46 HWD324 1A 47 HWD524 2A 48 HWD524 1A 49 HRF124 2A 50 HRF124 1A 51 HRI124 2A 52 HRI124 1A 53 Nugget R134A 54...

Page 38: ...ht 2 Evap Fan Cond Fan 22 RE336 1A Compressor Top Left Valve Bot Right Valve Light 1 Light 2 Evap Fan Evap Fan 2 Cond Fan 23 RE515 1A Compressor Light 1 Light 2 Evap Fan Cond Fan 25 RE524 1A Compresso...

Page 39: ...connection you should replace the thermistor and the thermistor harness Thermistor error information can be found in the Control Operations Service section This unit has two thermistors Thermistor one...

Page 40: ...nce accident or improper use maintenance instal lation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with the Mar...

Page 41: ...e without notice Such revisions do not entitle the buyer to corresponding changes improvements additions replacements or compensation for previously purchased products www marvelrefrigeration com 1260...

Reviews: