background image

OWNERS GUIDE

MARVEL UNDERCOUNTER REFRIGERATION

T H E   O R I G I N A L  R E F R I G E R A T I O N E X P E R T S S I N C E   1 8 9 2

F O R   M O D E L #  M L R E 2 2 4

OWNER’S GUIDE

MARVEL UNDERCOUNTER REFRIGERATION

T H E   O R I G I N A L   R E F R I G E R AT I O N   E X P E R T S   S I N C E   1 8 9 2

FOR MODEL # MLCP215

Summary of Contents for MLCP215

Page 1: ... E O R I G I N A L R E F R I G E R A T I O N E X P E R T S S I N C E 1 8 9 2 F O R M O D E L M L R E 2 2 4 OWNER S GUIDE MARVEL UNDERCOUNTER REFRIGERATION T H E O R I G I N A L R E F R I G E R AT I O N E X P E R T S S I N C E 1 8 9 2 FOR MODEL MLCP215 ...

Page 2: ...rvelrefrigeration com Got a Marvelous Design We would love to see how your Marvel product looks in its new home Send us photos at marketing marvelrefriger ation com and we might feature your Marvel home design on our website and social media Warranty Registration It is important you send in your warranty registration card immediately after taking delivery of your appliance or you can register onli...

Page 3: ...ce Electrical Cutout Product Dimensions Side by Side Stacking Installations Door Reversal Installing The Water Supply Maintenance Care and Cleaning Stainless Steel Maintenance Service Obtaining Service Wire Diagram Product Liability Warranty Claims Ordering Replacement Parts System Diagnosis Guide Compressor Specifications Thermistor Warranty 3 ...

Page 4: ... Important information to help assure a prob lem free installation and operation WARNING WARNING You can be killed or seriously injured if you do not follow these instructions WARNING State of California Proposition 65 Warning This product contains one or more chemicals known to the State of California to cause cancer WARNING State of California Proposition 65 Warning This product contains one or ...

Page 5: ... assumed by the retailer upon acceptance of the shipment Claims for loss or damage sustained in transit must be made to the retailer DO NOT RETURN DAMAGED MERCHANDISE TO THE MANUFACTURER FILE THE CLAIM WITH THE RETAIL ER NOTE WARNING WARNING Dispose of the plastic bags which can be a suffocation hazard CAUTION WARNING WARNING Help Prevent Tragedies Child entrapment and suffocation are not problems o...

Page 6: ...ce to shut down GFCI s are generally not used on circuits with power equip ment that must run unattended for long periods of time un less required to meet local building codes and ordinances Electrical Connection A grounded 115 volt 15 amp dedicated circuit is required This product is factory equipped with a power supply cord that has a three pronged grounded plug It must be plugged into a mating ...

Page 7: ...essary to gain clearance inside the rough in opening a hole can be cut through the adjacent cabinet and the power cord routed through this hole to a power outlet Another way to increase the available opening depth is to recess the power outlet into the rear wall to gain the thickness of the power cord plug Not all recessed outlet boxes will work for this applica tion as they are too narrow but a r...

Page 8: ...15V 60Hz 15A 105 lbs 47 6 kg Minimum rough in opening required is to be larger than the adjusted height of the cabinet A grounded 15 amp dedicated circuit is required Follow all local building codes when installing electrical and appliance Glass Door Shown F 211 2 54 6 cm D E H J G 8 ...

Page 9: ...r can be opened individually one at a time without interference Figure 10 However to ensure unobstructed door swing opening both doors at the same time 1 4 6 4 mm of space needs to be maintained between the units Hinge by Hinge Installation Mullion When installing two units hinge by hinge 13 16 22 mm is required for integrated models Additional space may be needed for any knobs pulls or handles in...

Page 10: ...ge Pin Screw to the opposite side Lower Hinge Bracket Before Reversal Upper Hinge Bracket After Reversal Lower Hinge Bracket After Reversal 5 Using a 5 32 Hex Key remove the Upper and Lower Hinge Brackets from the door saving all components screw into place on the opposite side of the door where plugs were removed Remove the Cam Closer from the Lower Hinge Bracket and attach it to the opposite sid...

Page 11: ...6 Remove the Toe Kick from the door and attach it to the opposite side DOOR REVERSAL Toe Kick Reversal 7 Reattach the Upper and Lower Hinges and Hinge Brackets to opposite sides Then install the door 11 ...

Page 12: ...13 FIlter head 3 8 NPT WARNING CAUTION CAUTION 12 ...

Page 13: ...vel approved ice machine cleaner and follow all label warnings and directions Incorrect chemical warranty To clean your ice machine you will need to purchase a nickel safe ice maker cleaner You can order ice machine cleaner part S41013789 at marvelrefrigeration com machine is ready to be cleaned While cleaning is needed UI will alternate between CL and ICE every 3000 cycles to indicate that the un...

Page 14: ...er will automatically return to ice making once clean cycle is complete Pour cleaning solution slowly onto the front edge of evaporator plate behind the grid cutter Evaporator plate Grid cutter Splash shield Lift fascia door up to ac cess evaporator plate Remove ice from bin Pull plug from the reservoir Once reservoir is empty replace plug Hold the Clean button tab for 5 seconds to show CL on the ...

Page 15: ...15 ...

Page 16: ... upon the installation location environmental and usage conditions Choosing a Cleaning Product The choice of a proper cleaning product is ultimately that of the consumer and there are many products from which to choose Depending upon the type of cleaning and the degree of contamination some products are better than others cleaning of most stainless steel products is to give the sur faces a brisk r...

Page 17: ...ort section In all correspondence regarding service be sure to give the service number serial number and proof of purchase Try to have information or description of nature of the problem how long the appliance has been running the room temperature and any additional information that may be helpful in quickly solving the problem Table B is provided for recording pertinent information regarding your...

Page 18: ...OOR BIN EVAP COMM LIGHT GRAY GRAY BLACK BLACK COMM POWER WHITE BLACK WHITE RED RED P N 41051002 WIRING DIAGRAM SATURN II 41051002 D WOODMAN 4 28 15 DRAIN PUMP OPTIONAL SERVICE CORD B REVISIONS REV DESCRIPTION DATE BY ECN A RELEASE TO PRODUCTION 4 30 2015 DWW 11798 B WAS DOOR SENSOR 6 3 2016 SM 12274 MUST BE RoHS and CALIFORNIA PROP 65 COMPLIANT AGA MARVEL DO NOT SCALE DRAWING SHEET 1 OF 1 B UNLESS...

Page 19: ...t in question The part that caused the damage must be returned to Marvel in its entirety The part must be clearly labeled with the serial number of the unit it was removed from the date and the servicer who removed the part If the service technician determines the damage is the result of installation issues water connection drain etc the consumer would be notified and the issues shall be resolved ...

Page 20: ...y labor 17 14862 05 0527 1 I I I Year Warranty Claims Day Factory use Only Units must be registered prior to warranty submittal Customers may register at www marvelrefrigeration com A proof of purchase is required We also accept the following information to update warranty New construction occupancy documents Closing paperwork Final billing Remodel Warranty parts will be shipped at no charge after...

Page 21: ...ber and part description Some parts will require color or voltage information Marvel requires the return of original parts we will inform you when the parts order is taken This requirement will be noted on your packing list A prepaid shipping label will be emailed to you Please enclose a copy of the parts packing list and be sure the model and serial numbers are legible on the paperwork Tag the pa...

Page 22: ...uum temperature temperature cool cool No Gas 0 PSIG to 25 Room Cool to hot temperature cool System Diagnosis Guide Condenser Capillary Evaporator Wattage Tube Very hot Warm Cold Normal Hot to warm Cool Cold Higher than normal Warm Warm Extremely Lower than cold near normal inlet Outlet below room temperature Top passes Room Extremely Lower than warm temperature cold near normal Lower cool or inlet...

Page 23: ...h are not hot or frozen Do not touch a bare circuit board unless you are wearing an anti static wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components Compressor SpeciAcations EMY45HER REFRIGERANT VOLTAGE FREQUENCY START WINDING R134A 115 127 VAC 60 Hz 11 Ohm at 77 F RUN WINDING RUN TO START LRA FLA STARTING DEVICE ...

Page 24: ... connection you should replace the thermistor and the thermistor harness Thermistor error information can be found in the Control Operations Service section This unit has two thermistors Thermistor one Zone Located along the right hand side wall It is used to maintain the operating temperature within that zone Thermistor two Evaporator Located on the evaporator It is used for defrost THERMISTOR FA...

Page 25: ...ence accident or improper use maintenance instal lation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with the Marvel User Guide The remedies described above for each warranty are the only ones that Marvel will provide either under these warranties or under any warranty arising by operation of law Marvel will no...

Page 26: ...t notice Such revisions do not entitle the buyer to corresponding changes improvements additions replacements or compensation for previously purchased products www marvelrefrigeration com Marvel Refrigeration 1260 E Van Deinse St Greenville MI 48838 616 754 5601 26 ...