Setting evaluation board 3
Setting motor operation
Three-position toggle switches ((1), (5), and (6) in the left
diagram) and level select pins ((3) and (4)) for setting the
operation of the TB67S128FTG and a rotary switch ((2) in the left
figure) for adjusting the AGC function are mounted.
In using these switches, short-circuit the jumper of JP_VDD (i.e.
initialize) or supply 5-V voltage from the VDD pin.
【
Switches of (1) and (6)
】
Tilting rightward: High level
Tilting leftward: Low level
Middle position Neutral. The input signal from the pins is valid.
【
Switches of (5)
】
Tilting downward: Low level
Tilting upward: High level
Middle position Neutral. The input signal from the pins is valid.
【
Switch of (2)
】
Four states can be selected by this rotary switch.
Position 1: Connecting to GND.
Position 2: Connecting to GND through a resistor of 100 kΩ.
Position 3: Connecting to VDD through a resistor of 100 kΩ.
Position 4: Connecting to VDD.
【
Switch of (3)
】
Short to leftward: Low level
Short to rightward: High level
Remove short pins, the input signal from the pins is valid.
【
Switch of (4)
】
Short to upward: Low level
Short to downward: High level
Remove short pins, the input signal from the pins is valid.
※
Refer to the datasheet for information on
how to use and set each function.
VDD pin
(1)
(4)
(3)
(5)
JP_VDD
(6)