GENERATOR
1. Adjusting bolt
2. Generator
3. Pivot bolt
4. “B” terminal wire
5. Coupler
6. Nut
7. Generator cover
8. Generator cover bolt
9. Generator bracket
10. Generator bracket bolt
11. Generator bracket nut
: Tightening Torque
REMOVAL
1) Disconnect negative cable (1) at battery (2).
2) Disconnect “B” terminal wire (3) and coupler (4) from generator
(5).
3) Remove generator cover (6).
4) Remove adjusting bolt (1) and loosen generator pivot bolt (2).
5) Remove generator with generator bracket (7).
INSTALLATION
Reverse above procedure giving specified tension to drive belt.
Refer to “Generator (Water Pump) Belt” for belt tension.
Tightening Torque
(a): 22 N·m (2.2 kg-m, 16.0 lb-ft)
(b): 50 N·m (5.0 kg-m, 36.5 lb-ft)
(c): 7 N·m (0.7 kg-m, 5.0 lb-ft)
6H-12
CHARGING SYSTEM
SH410