CLEANING
Clean frontal area of radiator cores.
INSTALLATION
Reverse removal procedures.
NOTE:
Refill cooling system with proper coolant referring to
COOLANT item of MAINTENANCE.
After installation, check each joint for leakage.
WATER PUMP
REMOVAL
1) Disconnect negative cable at battery.
2) Drain cooling system.
3) Remove timing belt and tensioner according to procedure de-
scribed in SECTION 6A.
4) Remove oil level gauge guide (1) with oil level gauge.
5) Remove generator adjusting arm (2).
6) Remove water pump (1), gasket and rubber seal (2).
INSPECTION
NOTE:
Do not disassemble water pump.
If any repair is required on pump, replace it as assembly.
Rotate water pump by hand to check for smooth operation and in-
spect water pump impeller for damage.
If pump does not rotate smoothly or makes abnormal noise, re-
place it.
6B-12
ENGINE COOLING
SH410