COOLING UNIT (EVAPORATOR)
1. Evaporator
2. A/C Evaporator thermistor
(Evaporator temperature sensor)
3. Expansion valve
4. Evaporator case
5. Packing
6. Drain hose
7. Air inlet door
REMOVAL
1) Disconnect negative (–) cable at battery.
2) Recover refrigerant from refrigeration system by using recovery
and recycling equipment.
3) Remove fresh air control cable (1) and disconnect evaporator
thermistor coupler (2).
4) Loosen suction hose and receiver/dryer outlet hose.
5) Open glove box lid (8).
6) Loosen cooling unit mounting bolts (3), nut (4) and screws (5).
7) Loosen instrument panel mounting bolt (6).
8) Remove cooling unit (7).
INSTALLATION
Reverse removal sequence to install cooling unit, noting the follow-
ing points.
If cooling unit or evaporator is replaced, pour 25 cc of refrigerat-
ing oil to compressor suction-side.
Install uniformly the evaporator pipe (1) to grommet.
AIR CONDITIONING (OPTIONAL)
1B-19