PINION (PLUNGER) RETURN TEST
As a next step to the above, disconnect negative lead and check
to make sure that pinion returns inward quickly.
NO-LOAD PERFORMANCE TEST
Connect test leads as shown in left figure and check that motor
runs without fail with pinion moved out. Also check that ammeter
indicates specified current.
Specified Current: 50A at 11.5V
6G-12