USER’S MANUAL
PowerPro UPS
PRO-650/850LCD
1. Inspection
The following items are inside the box:
User’s Manual
UPS
Power cord
Software CD
USB cable
Remove the PowerPro UPS from its packaging and inspect it for any damages that may
have occurred during shipping. If any damage is discovered, re-pack the unit and return
it to the place of purchase.
2. Placement of UPS
Place the PowerPro UPS in a protected area that is free of excessive dust and provide
at least 7.8 inches (20 cm) clearance on both sides for adequate airflow around the unit.
Avoid direct sunlight.
Avoid excessive heat.
Avoid excessive humidity or liquids.
Avoid excessive dust.
3. Connect UPS to Utility
Use the power cord that came with your UPS to connect the UPS directly to the wall
outlet.
Do not power the UPS using a surge suppressor or power strip
.
Battery Charging:
The unit is shipped from the factory with its internal battery fully charged, however, some
charge maybe lost during shipping and the battery should be recharged prior to use.
Plug the unit into an appropriate power supply and allow the UPS to charge fully by
leaving it plugged in for at least 8 hours.
4. Connecting Equipment to UPS
Connect the equipment to UPS Power Supplied outlets.
Battery Power Supplied Outlets & Surge Only Outlets
4 Battery Backup with Surge & 4 Surge only for NEMA outlets
4 Battery Backup with Surge for IEC outlets
Connect the computer, monitor, and external drive to the "UPS Power Supplied" outlets.
These outlets provide battery backup, EMI filtering, line conditioning, and surge
protection. Battery power is automatically provided in case of power failure.
Beware
of the Power Switch it must be kept in the "ON" position, otherwise, the UPS will
be disabled and your equipment will not be protected during a power failure.
5. Connect Modem/Phone/Fax/Network Line
The PowerPro UPS 650/850 protects a single
line RJ-11/45(1 in/1out) phone, modem, fax,
network device from surges when connected
through the UPS. Plug in connecting
internet line into the “IN” socket.
Use one more internet line cable in the
“OUT” socket and plug one other end to
the device input socket as shown in the
chart below.
6. Turn On/Off
To turn on the UPS unit, press the power On/Off Switch once. To turn off the UPS unit,
press the Power On/Off Switch again.
7. Cold Start Function
When the UPS is off and there is no power utility, it's still possible to cold start the UPS
unit to power the loads.
8. AC Auto Recovery
When the UPS is in battery mode and can no longer continue to supply battery power to
the loads, UPS will shut down. Once AC power is restored, the UPS will automatically
turn on and supply power to loads and charge battery.
UPS contains non-spill able sealed lead-acid batteries. It is important these batteries
are properly disposed of. Please see the label on the battery for recycling information
for proper battery disposal. If no information is available, please contact your local
authorized distributor or Maruson Customer Service at [email protected].
BATTERY RECYCLING INFORMATION
SOFTWARE INFORMATION
UPS INDICATORS & CONTROLS
No.
Indication
Description
1
Input Voltage
Indicate input voltage value. Input voltage will
blink continuously in back up mode.
2
Output Voltage
Indicate output voltage value.
3
Battery Capacity
Estimated battery capacity, the accuracy is
influenced by UPS operation mode and load
level.
4
Load Level
The load level, percentage of full load.
5
Fault
Icon is lighted: UPS is in fault condition and
alarm will beep continuously.
6
Battery
Icon is lighted: AC power is abnormal and UPS
is on back up mode.
7
Battery Fail
Icon is lighted: UPS battery is abnormal, please
check or replacement battery.
8
Normal
Icon is lighted: UPS is under normal status.
9
Overload
Icon is lighted: UPS is overload, buzzer will
beep continuously. Please remove some loads.
The PowerPro Series uses UPSilon 2000 software to allow additional monitoring
and management of the UPS statuses through your computer. Before installing the
software, connect the USB that came with the UPS to your computer and UPS. To
install the software, insert the CD that came with your unit to the computer and
follow the program set-up instructions. If the program requires a CD code or
password, please refer to the set of letters and/or numbers located on the CD.
UPSilon 2000 software supports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux,
Unix, and MAC. Features include:
Power flow display for monitoring UPS status.
Scheduled system shutdown/restart.
Warning notification via e-mail/pager/broadcast.
Scheduled UPS test.
Password security protection.
Remote monitoring/controlling via TCP/IP or internet.
Safely shut-down multiple systems.
Selectable user interface (background).
UPS parameter setting.
Recorded logs for analysis.