USER’S MANUAL 

PowerPro UPS 
PRO-650/850LCD 

 

1.  Inspection 

The following items are inside the box: 

 

  User’s Manual 

  UPS 

  Power cord 

  Software CD 

  USB cable 

 
Remove the PowerPro UPS from its packaging and inspect it for any damages that may 
have occurred during shipping. If any damage is discovered, re-pack the unit and return 
it to the place of purchase. 
 

2.  Placement of UPS 

Place the PowerPro UPS in a protected area that is free of excessive dust and provide 
at least 7.8 inches (20 cm) clearance on both sides for adequate airflow around the unit. 

 
 
 
 
 
 
 

 

  Avoid direct sunlight. 

  Avoid excessive heat. 

  Avoid excessive humidity or liquids. 

  Avoid excessive dust. 

 

3.  Connect UPS to Utility 

Use the  power cord that came  with  your UPS to connect the UPS  directly to the  wall 
outlet. 

Do not power the UPS using a surge suppressor or power strip

                                       

 

 
Battery Charging:   

                                             

 

The unit is shipped from the factory with its internal battery fully charged, however, some 
charge maybe lost during shipping and the battery should be recharged prior to use. 
Plug the unit into an appropriate power supply and allow the UPS to charge fully by 
leaving it plugged in for at least 8 hours. 
 

4.  Connecting Equipment to UPS 

Connect the equipment to UPS Power Supplied outlets. 
 

 

Battery Power Supplied Outlets & Surge Only Outlets 

 
4 Battery Backup with Surge & 4 Surge only for NEMA outlets 
4 Battery Backup with Surge for IEC outlets 

 
Connect the computer, monitor, and external drive to the "UPS Power Supplied" outlets. 
These outlets provide battery backup, EMI filtering, line conditioning, and surge 
protection. Battery power is automatically provided in case of power failure.     
 

Beware

 of the Power Switch it must be kept in the "ON" position, otherwise, the UPS will 

be disabled and your equipment will not be protected during a power failure. 
 

5.  Connect Modem/Phone/Fax/Network Line   

The PowerPro UPS 650/850 protects a single 
line RJ-11/45(1 in/1out) phone, modem, fax,   
network device from surges when connected   
through the UPS. Plug in connecting   
internet line into the “IN” socket. 
 
Use one more internet line cable in the 
  “OUT” socket and plug one other end to   
the device input socket as shown in the   
chart below. 

 

6.  Turn On/Off   

To turn on the UPS unit, press the power On/Off Switch once. To turn off the UPS unit, 
press the Power On/Off Switch again.   
 

 

 

7.  Cold Start Function   

When the UPS is off and there is no power utility, it's still possible to cold start the UPS 
unit to power the loads.   
 

8.  AC Auto Recovery 

When the UPS is in battery mode and can no longer continue to supply battery power to 
the loads, UPS will shut down. Once AC power is restored, the UPS will automatically 
turn on and supply power to loads and charge battery. 
 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

UPS contains non-spill able sealed lead-acid batteries. It is important these batteries 
are properly disposed of. Please see the label on the battery for recycling information 
for  proper  battery  disposal.  If  no  information  is  available,  please  contact  your  local 
authorized distributor or Maruson Customer Service at [email protected]

 

 

 

BATTERY RECYCLING INFORMATION

SOFTWARE INFORMATION

UPS INDICATORS & CONTROLS

No. 

Indication 

Description 

Input Voltage 

Indicate input voltage value. Input voltage will 
blink continuously in back up mode. 

Output Voltage 

Indicate output voltage value. 

Battery Capacity 

Estimated battery capacity, the accuracy is 
influenced by UPS operation mode and load 
level. 

Load Level 

The load level, percentage of full load. 

Fault 

Icon is lighted: UPS is in fault condition and 
alarm will beep continuously. 

Battery 

Icon is lighted: AC power is abnormal and UPS 
is on back up mode. 

Battery Fail 

Icon is lighted: UPS battery is abnormal, please 
check or replacement battery. 

Normal 

Icon is lighted: UPS is under normal status. 

Overload 

Icon is lighted: UPS is overload, buzzer will 
beep continuously. Please remove some loads. 

The PowerPro Series uses UPSilon 2000 software to allow additional monitoring 
and management of the UPS statuses through your computer. Before installing the 
software, connect the USB that came with the UPS to your computer and UPS. To 
install the software, insert the CD that came with your unit to the computer and 
follow the program set-up instructions. If the program requires a CD code or 
password, please refer to the set of letters and/or numbers located on the CD.     
 
UPSilon 2000 software supports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux, 
Unix, and MAC. Features include: 
 

 

Power flow display for monitoring UPS status.   

 

Scheduled system shutdown/restart.   

 

Warning notification via e-mail/pager/broadcast.   

 

Scheduled UPS test.   

 

Password security protection.   

 

Remote monitoring/controlling via TCP/IP or internet.   

 

Safely shut-down multiple systems.   

 

Selectable user interface (background).   

 

UPS parameter setting.   

 

Recorded logs for analysis.   