Inspection
Remove the UPS from its packaging and inspect it
for damage that may have occurred during shipping.
If any damage is discovered, repack the unit and
return it to the place of purchase.
Placement
Charging
Install the UPS unit in any protected environment
that provides adequate airflow around the unit, and
is free from excessive dust, corrosive fumes and
conductive contaminants. Do not operate your UPS
in an environment where the ambient temperature
or humidity is high. On the other hand, place the
UPS unit away from monitor at least 20cm to avoid
interference.
This unit is shipped from the factory with its internal
battery fully charged. however, some energy may be
lost during shipping so the battery should be
recharged before using it. Plug the unit into an
appropriate power supply and allow the UPS to
charge fully by leaving it plugged in for 8 hours.
Connect one computer-related device into each of
the power receptacles supplied on the back of the
UPS (maximum of three devices).
To turn on the UPS unit, press the power switch lightly.
To turn off the UPS unit, press the power switch again
(When Swith ON
,
The LED lighting.).
The LED will always turns on when UPS works,
including in off charging mode and fault mode.
When LCD start to work, it will display all information
for 3s
Plug incoming internet line into the “In” socket at the
back of the UPS. Use one more Internet line cable
and plug one end of the Internet line cable to the
“Out” socket at the back of the UPS. Plug the other
end to the modem input socket as shown.
Computer Connection
Modem/Phoneline Connection
Turn On/Off
LCD Display Specification
1).When in normal mode, it will display as below.
2).When in AVR mode, it will display as below. And the
mark
will flicker every 1second.
3).When in battery mode, it will display as below.
And the mark
will flicker every 1second.
Note: If I/P-V<40V
,
input voltage will display “000”
4).When in off charging mode, it will display as below.
Note: the output voltage always is displayed as “000”
in off charging mode.
5).When in fault mode, it will display as below. “FAULT”
character and the reason of fault only.
Note: the fault code will be showed in fault mode.
6).Load level definition:
Load LEVEL
Load bar Indication
0%~25%
25%~50%
50%~75%
75%~100%
7).Battery capacity definition:
Battery voltage
≤11
V
11
V
≤
Battery voltage
≤11.
5V
11.
5V
≤
Battery voltage
≤1
2
.5
V
Battery voltage
≥12.
5V
8).When over load, the mark
will flicker every
1second.
1second.
9).When battery low, the mark
will flicker every
5
4
6
7
3
2
1
UPS System Description