background image

                024-001-750  MOD 8     11/05/07                            Page 1 of 8                                POWER UNITS

Centurion Safety Products Ltd. Howlett Way, Thetford, Norfolk, IP24 1HZ, UK

Tel. 0044 (0)1842 754266   Fax. 0044 (0)1842 765590

Martindale

USER INSTRUCTIONS:

MAGNUM P2/P3 POWERED RESPIRATORS

Models covered
Power Units :

M23/1000, M23/2000, M23/8500

Powered Respirator kits:

M23/1000/CB, M23/2000/CB, M23/8500/CB

                                                    (Power Unit, 8-hour Battery and UK Charger)

Available Headpieces:

See section 2 below

Before  using  the  system  it  is  essential  that  you  read  these  instructions  and  ensure  that  the  correct  equipment  has
been selected.  Always be aware of the limitations of use of the equipment and that it is appropriate to the task.

1.

WARNINGS

If these instructions are not followed or the unit is used incorrectly the system may not offer protection to EN12941/42 or EN 146.
Power units offer 

NO

 protection unless a main filter(s) is fitted.

In a power off situation the headpiece offers no respiratory  protection  and  rapid  CO2  build-up  and  oxygen  depletion  may  also  result.    This  is  an

abnormal situation.

Power off is an abnormal situation regardless of whether a full hood, half suit or mask is used.
At high work rates the pressure inside the headpiece may become negative at peak inhalation.
The system should not be used in oxygen deficient or oxygen enriched atmospheres.
The user must ensure that the nature of the hazard is identified and that the system offers an adequate level of protection.
This unit should not be used where the nature of the hazard is unknown.
This unit is NOT intrinsically safe and therefore should not be used in explosive atmospheres
Be aware that the hose protrudes from the back of the headpiece and take care to avoid snagging.
In high wind velocities the assumed protection levels may not be achieved.
The full hood and half suit provide no protection against impact to head, face or eyes.

Respiratory protection will be reduced unless the hood is correctly fitted and properly maintained.
Do not confuse the markings on any filter which relate to standards other than EN12941 or EN12942 with the classification of this device when
used with that filter. The classification for EN12941 will begin with "TH" and for EN12942 will begin with "TM". Filters should only be fitted to the
power unit, do not attempt to fit them directly to a hood or helmet.

2. 

LIST OF PARTS , AVAILABLE HEADPIECES, APPROVALS / SPECIFICATION, NOMINAL AND ASSIGNED
PROTECTION FACTORS

kits

Power Unit

8 hr Battery

UK Charger

Standard Class

M23/1000/CB

(5)

M23/1000

M23P2/4B

M23P2/4BC

EN146

THP2

M23/2000/CB

(3)

M23/2000  

M23SPB

M23UIC 

EN12941

TH2/TH3

(6)

M23/8500/CB

M23/8500

M23SPB

M23UIC 

EN12941/2

(4)

TH3/TM3

(1)

TH2

(2)

(1)

The M23/8500 and Full Facemask is approved with the full range of Martindale DIN 40 gas/combination filters.

(2)

The M23/8500 & TH2 headpieces are approved for use with the Fitta range of Combination Gas/Dust filters (M09A1P2) .

(3)

Optional 4 hour battery and charger available for the 2000 power units – M23P2/4B battery and M23P2/4BC charger.

(4)

All headpiece systems are to EN12941 or EN 146 with the exception of the Full facemask, which is to EN12942.

(5)

 Note: Heavy Duty Battery M23HD4B and charger M23UIC are also available for use with the Magnum 1000 and will typically give durations of

12 hours+.

(6)

 Note: Magnum 2000 only conforms to TH3 when used with M23P3/5 filters and M23LHF otherwise it conforms to TH2

(7)

 Note: Nominal Protection factors of headpieces used with Magnum 1000 is 20

 

Nominal and Assigned Protection Factors for Headpiece/Power Unit kits

(Refer to Compatibility table below for suitable power units)

NPF

APF (UK)

Headpiece

code

dust

gases

(1,2)

dust

gases

(1,2)

Rigid Polycarbonate Visor with Saronex Hood

M23RVSN

50

(7)

50

20

20

Flip up Polycarbonate Visor

M23FUVN

50

(7)

50

20

20

Helmet with Flip-up Polycarbonate Visor

M23HFUV

50

(7)

50

20

20

High Temperature Helmet with Clear Triacetate Flip up Visor

M23HFUVHTT

50

(7)

50

20

20

High Temperature Helmet with Gold Polycarbonate Visor

M23HFUVHTGP

50

(7)

50

20

20

Automatic Welding Visor

M23AWSN

50

(7)

50

20

20

Fixed Shade Welding Visor

M23FSWVN

50

(7)

50

20

20

Lightweight P3 Tyvek F Hood        

M23LHF

50/500*

50/500*

20/40*

20/40*

Full Hood

M23FH/8

500

-

40

-

Half Suit

M23HS/8

500

-

40

-

Full facemask with twin hose

M23FF

2000

2000

40

40

* Note NPF=500 & APF=40 when M23LHF is used with TH3P Filters (e.g. M23P3/5 or M23P3SL/6) and M23/2000 or 8500 otherwise the M23LHF
has NPF=50

(7)

 & APF=20.

A  detailed  table  showing  the  exact  classifications  and  protection  levels  is  given  in  the  headpiece  instructions  (024-001-692)  supplied  with  each
headpiece which must be read in conjunction with these instructions.

Summary of Contents for MAGNUM M23/1000

Page 1: ...ll begin with TM Filters should only be fitted to the power unit do not attempt to fit them directly to a hood or helmet 2 LIST OF PARTS AVAILABLE HEADPIECES APPROVALS SPECIFICATION NOMINAL AND ASSIGN...

Page 2: ...hargeable battery pack which requires charging before use Ensure you are using the correct charger for your battery pack See Section 2 Standard Charger M23P2 4BC or M23HD4BC When charging the battery...

Page 3: ...rs e g M23 A2B2 P3 1000ppm 100mg m3 Dust filters TH2P e g M23P2 5 N A 400mg m3 Dust filters TH3P TM3P e g M23P3 5 N A 200mg m3 5 2 MAGNUM 1000 2000 Power unit M23 1000 M23 2000 Pre filters General The...

Page 4: ...suring that it is properly snapped shut If a pre filter is not used the main filter should be changed immediately the clogged filter alarm sounds indicates or the air flow indicator indicates reduced...

Page 5: ...d filter medium Do not use filters after their expiry date Do not use filters with no or damaged filter seal caps 6 AIR FLOW INFORMATION AND WARNING DEVICES MAGNUM 1000 POWER UNIT The Power unit is de...

Page 6: ...rious conditions The Power unit will give an audible and visual alarm when either the clogging of the filter causes the airflow to drop to the minimum design flowrate or when the battery voltage drops...

Page 7: ...here the filter is fitted If line A is fully visible then the unit has sufficient airflow If line A is not visible replace the filters If you have both replaced the filter and fully charged the batter...

Page 8: ...without charge 11 SPARES Description Part Number Shower resistant plastic shroud for 8500 unit M23PS Comfort pad item 11 M23CP L Spare Standard Belt item 1 M23B Plastic Belt Wipe clean for decontamina...

Reviews: