Page 1: ...EZ365 SOCKET TESTER Instruction Manual...

Page 2: ...Symbols and Markings 1 1 2 Precautions 2 2 Introduction 3 2 1 Inspection 3 2 2 Description 3 3 Operation 4 3 1 Description of Indicators 4 3 2 Self Test 4 3 3 Buzzer 5 3 4 Using the EZ365 5 3 4 1 Wiri...

Page 3: ...uct information are available at www martindale electric co uk 1 1 Meaning of Symbols and Markings Caution risk of danger and refer to instructions Caution risk of electric shock Equipment protected b...

Page 4: ...d under the conditions and for the purposes for which it has been constructed and specified Before each use the socket tester should be examined for damage cracks cuts or scratches Do not use if damag...

Page 5: ...mpedance falls within If the wiring is faulty or the mains voltage is not within limits the earth loop impedance test is not performed The EZ365 also indicates if the mains voltage is below 195V or ab...

Page 6: ...he wiring or if the mains supply is 195V or 270V or if the neutral to earth voltage is 30V Note 1 The loop test will not be performed and the loop test indicators will not illuminate if there is a wir...

Page 7: ...and 500 Slow pulsed tone Pulse repetition frequency 3Hz Faulty wiring Supply voltage out of tolerance RCD did not trip following RCD test Pulsed tone increasing to continuous tone RCD trip test will b...

Page 8: ...be indicated by the LED sequences of figure 1 on the lower row of LED s If a wiring fault is detected or the supply voltage is out of tolerance the top loop indicator LED s will not illuminate as a l...

Page 9: ...L Socket Under Test Wiring N E L E N L E E L N N L OPEN E L OPEN N L OPEN L E OPEN L N N OPEN L E OPEN L L OPEN E L OPEN N L E OPEN L N OPEN E L OPEN N L OPEN L E N L E E L N E L N N E L L N L L N L E...

Page 10: ...it under test is between 1 7 and 5 or if the top left hand indicator is red then the measured earth loop impedance is between 10 and 100 Refer to the latest edition of the IET Wiring Regulations BS 76...

Page 11: ...te this fault condition once the finger has been removed from the touch pad In the event of a fault being indicated investigation should only be carried out by a suitably qualified electrician 3 4 4 R...

Page 12: ...eing operated in line with normal practice when using electrical test equipment 3 4 6 Possible Effects on Accuracy when Measuring Earth Loop Impedance Where supply circuits under test have highly indu...

Page 13: ...water dampened soft cloth After cleaning dry and allow to remain in a dry environment for 2 hours before use 4 2 Repair Service There are no user serviceable parts Return to Martindale Electric if fau...

Page 14: ...ce free of charge repair or replacement of a defective product which is returned to Martindale within the warranty period This warranty is the buyer s sole and exclusive remedy and is in lieu of all o...

Page 15: ...70V 5 Earth neutral voltage high indication 30V 5 Open earth indication 500 10 RCD test current at 195V 30mA Duration of RCD test current 300ms Polarity reversal test Note 1 Measurement accuracy can b...

Page 16: ...ccessories Phase Rotation Testers Proving Units Socket Testers Thermometers Probes Test Leads Voltage Indicators Specialist Metrohm Testers Specialist Drummond Testers Check out what else you can get...