background image

EASYPAT 2100

PAT TESTER

MARTINDALE

E L E C T R I C

Trusted by professionals

INSTRUCTIONS

2

SAFETY INFORMATION: Always read before proceeding.

WARNING

These instructions contain information and warnings that are necessary for
safe operation and maintenance of the EasyPat. It is recommended that you
read the instructions carefully and ensure the contents are understood.
Failure to understand the instructions and comply with warnings and
instructions herein can result in serious injury, damage or even death.

In order to avoid the danger of electrical shock, it is important that proper
safety measures are taken when working with voltages exceeding 30V AC
rms, 42V AC peak or 60V DC. Never exceed the maximum allowable input
level for each function and range. Refer to the specifications for maximum
inputs. Never touch exposed wiring, connections or live circuits. 

The EasyPat must only be used in conditions and for the purpose which it
has been constructed. Attention should be paid to safety instructions,
technical specifications and use of the EasyPat in dry surroundings.

Always inspect your meter, test leads and accessories for any sign of
damage before use. If any abnormal conditions exist (e.g: broken test leads,
cracked case, display not reading, etc.), do not attempt to use it. Do not
expose it to direct sunlight, excessive temperature or moisture.

Keep these instructions for future reference. Updated instructions and
product information are available at: www.martindale-electric.co.uk.

SYMBOLS:

Equipment complies with relevant EU Directives

AC (Alternating Current)

Ground

Direct Current

Equipment protected by Double Insulation (Class II)

Caution - refer to accompanying documents

Caution - risk of electric shock

3

CONTENTS

1

1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9

2

2.1
2.2
2.3

3

3.1
3.2
3.3
3.4
3.5
3.6

4

4.1
4.2
4.3
4.4
4.5

Introduction

Description
Earth / Continuity (8A and 25A)

 

Earth / Continuity (

2

00mA)

 

Insulation
Run Current
Run Leakage
Flash
Unpacking & Inspection

 

Spares & Accessories

Specifications

Electrical Specification

 

Mechanical Specification

 

Environmental Specification

Operation

Earth Continuity (8A and 25A)

 

Earth Continuity (

2

00mA)

 

Insulation
Run
Flash
Lead Test

Maintenance

Cleaning
Calibration
Repair & Service
Storage Conditions
Warranty

4

1. INTRODUCTION

Fig. 1

1.1 Description

The Martindale EasyPat is an LCD indicating portable appliance tester, which is

 

housed in a rugged injection moulded case with a removable lid. The base of the

 

case contains the complete power and electronic circuitry. Basic safety

 

instructions are presented on the inside of the lid, and a pannier bag, which

 

provides storage for the flash gun, supply adaptors and comprehensive instruction

 

manual, clips onto the top of the lid.

Operation of the Martindale EasyPat is straightforward. The five main tests,

 

continuity, insulation, run current, run leakage and flash, provided by this

 

instrument are selected by depressing one of five push-button switches on the

 

front panel. A three position rocker switch selects a test current of 

2

00mA DC, 8A

 

AC or 25A AC for the continuity test. While the key is depressed the relevant

 

measurement is displayed on the large, custom LCD Display.

The Martindale EasyPat allows fast, simple testing on all tools, appliances and IT

 

equipment in accordance with the recommendations of the Electricity At Work Act,

 

the Health And Safety Executive and the Electronic And Business Equipment

 

Association. It should be noted that Class I equipment is earthed whereas Class II

equipment is not earthed (double-insulated), usually denoted by the symbol 

.