Safety information 

 

 

Safety information 

The following symbols are used to identify important safety information: 
 

 

 

 

 

 

 

 

 

Caution! Safety 

hazard. Risk of 

personal injury. 

Caution! Burn 

hazard. Hot 

surface. Do not 

touch. 

Danger! 

Hazardous 

voltage. Contact 

will cause electric 

shock. 

Caution! Fire 

hazard. 

 

 

 

 

 
 

 

 
Warning! This product is not for household use. It presents risks of injury due to 
electric shock, burns, falls and respiratory problems! 

Read this manual before operating the machine, follow the safety precautions 
listed below, and observe all warnings in this manual and printed on the 
machine. Use the system only as described in this manual and in accordance 
with local laws and regulations. 
 
If you have questions about how to operate the machine safely, or if you have 
followed the instructions in this manual and the machine is malfunctioning, 
please contact Martin Service. 
 

P r e v e n t i n g   e l e c t r i c   s h o c k s  

 

Always ground (earth) the machine electrically. 

 

Use only a source of AC power that complies with local building and 
electrical codes, and that has both overload and ground-fault protection. 

 

Before connecting the fog machine to power, check that the voltage 

indicated on the machine’s serial label matches your local AC power 
voltage. If your AC power voltage does not match, do not use the 
machine. Contact Martin Service for assistance. 

 

Before using the machine, check that all power distribution equipment 

and cables are in perfect condition and rated for the current 
requirements of all connected devices. 

 

If the machine or any cables connected to it are in any way damaged, 
defective, wet, or show signs of overheating, stop using the machine 
and contact Martin Service for assistance. If the supply cord is 
damaged, it must be replaced by a special cord or assembly available 

from the manufacturer or its service agent. 

 

Disconnect the machine from AC power before servicing and when not 
in use. 

 

This system is not waterproof and should not be exposed to wet 

outdoor conditions. Do not immerse in water or any other liquid. Do not 
expose to high-pressure water jets. 

 

Do not spill fluid over or inside the machine. If fluid is spilled, disconnect 

AC power and clean with a damp cloth. If fluid is spilled onto electronic 
parts, take the system out of service and contact Martin for advice. 

Summary of Contents for JEM ZR44 Hi-MASS

Page 1: ...user manual ZR44 HI MASS P N 35010032 D TM ...

Page 2: ... any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual Martin Harman and all other trademarks in this document pertaining to services or products by Martin Professional or its affiliates and subsidiaries are registered as the property of Harman International Indust...

Page 3: ...n the power 11 Control settings 12 Overview 12 Manual firing 12 Setting fog output level 12 Setting the Timer 12 Setting the master slave link mode 12 Digital remote control 13 Overview 13 Functions 13 DMX control 14 Overview 14 Connection 14 DMX functions 14 Setting the DMX address 15 Approved fluid types 16 Pro Clean Supreme Fluid 17 Basic service 18 Cleaning 18 Fuse replacement 18 Troubleshooti...

Page 4: ... both overload and ground fault protection Before connecting the fog machine to power check that the voltage indicated on the machine s serial label matches your local AC power voltage If your AC power voltage does not match do not use the machine Contact Martin Service for assistance Before using the machine check that all power distribution equipment and cables are in perfect condition and rated...

Page 5: ...vents and ensure free and unobstructed air flow to and around the machine Keep the machine at least 600 mm 24 in away from combustible and heat sensitive materials Do not operate the machine if the ambient temperature Ta is below 5 C 41 F or above 40 C 104 F Do not operate the machine if the relative air humidity exceeds 80 Preventing injuries Ensure that the surface on which the machine is locate...

Page 6: ...d types on page 16 or you may cause the release of toxic gases presenting a severe health hazard You will also probably damage the machine Do not create dense fog in confined or poorly ventilated areas Do not expose people with health problems including allergic and or respiratory conditions such as asthma to fog output Do not point fog output directly at a person s face or at face height ...

Page 7: ... the new JEM ZR44 Hi Mass encompasses what Martin fog effect machines are all about state of the art technology high quality and ruggedness Congratulations on your purchase of this fog machine from Martin Details of the full range of Martin products are available on our website at www martin com Features at a glance Robust road worthy design Integrated analog remote control DMX with RDM standard H...

Page 8: ...nector Main power switch Dip switch DMX address AVR program upload socket 5 pin DMX input and link 3 pin DMX input and link Fluid Reservoir If suspending overhead Wrap safety cable under hanging bracket and secure Hanging bracket Remove remote control to access Digital remote accessory socket Fog output nozzle ...

Page 9: ...at the rear of the machine to the ON position and press the grey stand by button The Ready LED will flash indicating the machine is heating up allow around 10 minutes for the machine to reach operating temperature Once the machine has heated the Ready LED will stop flashing and be permanently on Making fog Once the machine has heated up hold the FOG button on the remote to start the fog output It ...

Page 10: ...hine over areas where people will be underneath Ensure that there is at least 100 mm 4 in clearance around the machine and at least 600 mm 24 in in front of the fog output AC power Before using the machine ensure that a grounding type earthed power plug that fits the local power outlets is installed on the power cable DANGER Make sure the power plug is correctly rated For EU models use a plug rate...

Page 11: ...and meets the location requirements stated on page 10 the operator is familiar with and able to comply with the requirements for safe operation listed on page 4 the fog fluid is one of the genuine Martin fluids listed under Approved fluid types on page 16 the machine is electrically grounded earthed the AC power distribution circuits and lines are adequately rated for the current load Turning on t...

Page 12: ...BUTTON When the timer is being used the timer values can be adjusted by a factor of 8 i e a 5 second minimum run time becomes 40 seconds a 10 second delay time becomes 1 minute 20 seconds TIMER ENGAGE This will engage the timer to fire the machine according to the present settings OUTPUT CONTROL Turning this knob clockwise will increase the output of the machine if turned fully anti clockwise ther...

Page 13: ... Fog button turns fog output on and off Press once to start fog and again to stop Timer button turns the fog timer on and off Fog level setting Fog 0 100 Timer run time off time settings 0 90 seconds Run mode RUN The Fog button works by setting RUN to or The Timer button sets RUN to or These buttons are simply a quick way to control this menu function Display Timer button Fog button XLR socket XLR...

Page 14: ...on the rear panel for DMX connection The wiring is shown below Connector pin function 1 Ground 2 Data Cold 3 Data Hot For best results use cable designed for high speed digital data transmission DMX functions The fog machine operates from a single DMX channel which gives proportional control of fog density from 0 100 DMX Level function 0 12 No fog 13 255 Fog at variable density 13 minimum 255 maxi...

Page 15: ... 458 490 1 1 0 1 0 11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491 0 0 1 1 0 12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 2...

Page 16: ...o its incredible long hang time characteristics In environments unaffected by extraction and air conditioning i fog can be expected to last Pro Steam Simulation Steam simulation fluid specifically designed for steam effects Creates a white burst but is fast dispersing In order to optimise the machines temperature setting the dip switch on the rear marked Low Temp should be set down to position 1 R...

Page 17: ...sing Pro Clean Supreme every 200 hours or once a month depending on usage will prolong the life of the heat exchanger in Martin fog and haze machines Connect Pro Clean Supreme fluid to the fogger or hazer then allow the unit to heat When fully ready activate the machine or remote for approximately 30 45 minutes use the timer function if available When completed replace cleaning fluid with appropri...

Page 18: ... to 10 hours after use Remove dust from the air vents with a soft brush cotton swab vacuum or compressed air Clean fog fluid residues from the fog output of the machine using a damp cloth Clean the outer casing with a damp cloth only Fuse replacement The main fuse for the fog machine is located on the electronics board inside the unit DANGER Disconnect the power supply before removing any covers L...

Page 19: ...ress setting incorrect Change DMX address page 15 Poor connection in DMX line Check DMX cables and connections Fog output is weak Machine requires priming Prime machine page 10 Wet greasy non uniform fog output fluid drips or spits from nozzles or very loud noise when firing machine Incompatible fog fluid Use only approved fluids Machine appears dead Mains fuse blown Replace fuse page 19 No power ...

Page 20: ...USITT DMX512 A RDM compliance ANSI ESTA E1 20 RDM Construction Color Black silver Housing Steel and aluminium Fluid reservoir 9 5 l drop in Heat exchanger 1800 W thermally protected Fluid pump Oscillating piston high pressure Fluid management Fluid out sensing sealed for transportation External fluid control Fluid sensing Drip tray Optional bolt on tray with reusable collection sponge Installation...

Page 21: ...input cable US Neutrik PowerCON molded NEMA 5 15P 2 5 m 8 2 ft P N 11501042 User manual P N 35010032 Accessories JEM ZR44 Digital Remote Control P N 92765037 JEM ZR44 Ducting Kit with 5 m 16 4 ft ducting P N 92625005 JEM ZR44 Drip Tray P N 92620011 Approved Fluids JEM Pro Smoke Studio JEM Pro Smoke Super JEM Pro Smoke High Density JEM i fog Fluid JEM Pro Steam Simulation Fluid JEM Pro Clean Suprem...

Page 22: ...22 Technical Specifications Specifications subject to change without notice For the latest technical specifications see www martin com ...

Page 23: ...23 ...

Page 24: ...24 Notes Notes ...

Page 25: ...25 ...

Page 26: ...t and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of Martin products ...

Page 27: ...27 ...

Page 28: ...Martin Professional A S Olof Palmes Allé 18 DK 8200 Aarhus N Phone 45 87 40 00 00 Internet www martin com ...

Reviews: