MLA Mini
User Guide V1.0
22
MLA MINI
USER GUIDE
CABLING, CONNECTING UP
The electrical connections for a single 4 x Mini array plus an MSX sub are straightforward.
U-NET
1
!
SERIAL
No.
OUTPUT
INPUT
LINK
U-NET
2
!
POWER
ANALOGUE INPUT/LINK
PIN 1 GND
PIN 2 HOT
PIN 3 COLD
INPUT IMPEDANCE
20K Ohms BALANCED
Always check signal
source drive capability
before parallelling
multiple inputs
AES / EBU INPUT / LINK
PIN 1 GND
PIN 2 SIGNAL
PIN 3 SIGNAL
RECEIVE AND
TRANSMIT TERMINATION
IMPEDANCE 110 Ohms
BALANCED
WARNING!
SUSPENSION OF THIS LOUDSPEAKER SHOULD ONLY BE UNDERTAKEN BY TRAINED AND
QUALIFIED PERSONNEL. REFER TO THE RIGGING MANUAL FOR FURTHER INFORMATION
Made in England by
UNIT 2, CENTURY POINT, HALIFAX ROAD, CRESSEX BUSINESS PARK, HIGH WYCOMBE, HP12 3SL
TEL 01494 535312 FAX 01494 438669 www.martin-audio.com
MARTIN AUDIO LTD
FOR FURTHER INFORMATION CONSULT PRODUCT MANUAL
Electrical Safety
UL 60065
IEC 60320 POWERCON CONNECTOR REQUIRED ON MAINS INPUT CABLE.
MAINS OPERATING VOLTAGE 100-240V ~50-60Hz 900W
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS AMPLIFIER. REMOVAL
OF COVERS BY UNAUTHORISED PERSONNEL WILL INVALIDATE WARRANTY
AND MAY RESULT IN EXPOSURE TO LETHAL HIGH VOLTAGE AND CURRENT.
POWER
MINI
USB
PRESET
SELECT
TO MLA MINI
OUTPUT
TO MLA MINI
THIS DEVICE COMPLIES WITH PART
15 OF THE FCC RULES FOR THE
U.S.
AND
THE
ICES-003
FOR
CANADA. OPERATION IS SUBJECT
TO THE FOLLOWING CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE
HARMFUL INTERFERENCE, AND (2)
THIS DEVICE MUST ACCEPT ANY
INTERFERENCE
RECEIVED,
INCLUDING INTERFERENCE THAT
MAY
CAUSE
UNDESIRED
OPERATION.
NEUTRIK
NEUTRIK
1
2
3
PUSH
PUSH
NEUTRIK
NEUTRIK
6
LIECHTENSTEIN
LIECHTENSTEIN
RISK OF ELECTRIC
CAUTION
SHOCK DO NOT OPEN
THIS EQUIPMENT
MUST BE EARTHED
WARNING
IP25
1. AC Mains – connect the power supply cable to the Neutrik® PowerCON TRUE1 connector
on the rear panel of the MSX sub. Do not connect the other end of the cable to a live AC
supply at this stage.
2. Connect the amplifier outputs to the MLA Mini cabinets using the pre-made cable
assembly supplied (if length permits - configuration-dependent. Some configurations
will require longer cables). Note the colour-coding (orange and green); also note the
wiring diagram on the MSX rear panel adjacent to each of the OUTPUT connectors.
Plug the orange NL8 connector into the left-hand OUTPUT socket. Plug the green NL8
connector into the right-hand OUTPUT socket. Note that the other ends of the cable have
different lengths of ‘tail’. This is to identify which cable connects to which cabinet.
IMPORTANT:
The wiring instructions differ between ground stack configurations and flown
configurations. Use the correct set of instructions for the arrangement you are using.
Ground stack configurations:
•
Plug the orange-coded NL4 with the shorter tail into Cabinet 2 (the
second cabinet from the bottom of the array)
•
Plug the orange-coded NL4 with the longer tail into Cabinet 3 (the
third cabinet from the bottom of the array)
•
Plug the green-coded NL4 with the shorter tail into Cabinet 1 (the
bottom cabinet in the array)
•
Plug the green-coded NL4 with the longer tail into Cabinet 4 (the top
cabinet in the array)
-‐14.5°
12m
2m
1.
57m
0.5°
6.5°
6.5°
-‐17.5°
17m
2m
1.
57m
0.5°
6.5°
6.5°
-‐11°
17m
2m
1.
57m
0.5°
0.5°
10°
ANALOGUE
INPUT
ANALOGUE
INPUT
ANALOGUE
INPUT