3
MAINS CONNECTION
The M2 is supplied with a captive mains lead with an integral U.K. BS1363
3 pin plug. Should the moulded plug be removed and another plug
substituted the cable must be re-wired as below.
GREEN/YELLOW
-
EARTH
BROWN
-
LIVE
BLUE
-
NEUTRAL
WARNING: The M2 Controller must always be operated with the mains
safety earth connected.
The M2 is supplied from the factory in either 100-120V or
200-240V versions
Mains voltage tol/- 10% on each setting
Fuse: - type ‘T’ semi-delay 200mA (L) 100-120V
Fuse: - type ‘T’ semi-delay 100mA (L) 220-240V
NO ATTEMPT SHOULD BE MADE BY THE USER TO CHANGE THE
MAINS OPERATING VOLTAGE FROM THAT SUPPLIED, REFER TO
QUALIFIED PERSONNEL ONLY
4 SAFETY
FIRST
It is important that loudspeaker systems are used in a safe manner.
Please take some time to review the following points concerning safe use
of ICT500 compact loudspeakers.
Professional loudspeakers are capable of producing extremely high sound
levels and should be used with care. Hearing loss is cumulative and can
result from levels above 90dB if people are exposed for a long period.
Never stand close to loudspeakers driven at high level.
Martin Audio – M2 and ICT500
E
NGLISH
3
This equipment must be earthed.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DO NOT EXPOSE TO RAIN
OR MOISTURE
It should not be necessary to remove any protective earth or signal cable
shield connections.
!
CONTENTS
<
>
GUIDES