background image

4

MAINS CONNECTION

The CS265P is supplied in either 220-240 volt or 100-120 volt versions.
Before connecting to the mains, ensure that the version you have is the
correct voltage.

The CS265P is fitted with an IEC 320 mains receptacle with integral fuse
holder.  The 2 metre mains lead supplied is fitted with a 3-pin mains plug to
UK BS1363.

Should this mains plug be removed and another plug substituted, the cable
must be rewired as follows:

GREEN/YELLOW 

-  EARTH

BROWN

-  LIVE

BLUE

-  NEUTRAL

WARNING:
The CS265P must always be operated with the mains safety earth
connected

Fuse rating for 220-240V version 

2 amp type T(L)

Fuse rating for 100-120V version

-

4 amp type T(L)

Voltage tolerance on each version -5% +10%

5

INSTALLATION

The CS265P may be mounted in any orientation provided that there is
adequate airflow around the power module to assist cooling.  It should not
be mounted in an environment where the ambient temperature can exceed
40 degrees C.  This will result in thermal shutdown of the power amplifier
module.  Operation will be automatically resumed once the temperature has
returned to a safe level.  

Martin Audio – CS265P

E

NGLISH

3

This equipment must be earthed.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

DO NOT EXPOSE TO RAIN

OR MOISTURE

It should not be necessary to remove any protective earth or signal cable
shield connections.

!

CONTENTS

<

>