background image

MT840 User’s Manual V1.1

 

29

 

 

Check Host MAC Address 

To check scanner’s MAC address, please connect to a host device and scan below configuration 

barcode.

 

 

Check Host MAC Address 

 

 

Check Battery Life 

To check scanner’s battery life, please connect to a host device and scan below configuration 

barcode. 

 

 

Check Battery Life 

 

 

 

 

 

 

ScanLink 

ScanLink is a connection method that turns the scanner into a master device, which initiates the 

Bluetooth connection with the target host device (now a slave device). This, as a result, saves user 

the trouble of going through numerous setup procedures on the host device to establish 

connection. 

 

Simply generate ScanLink barcode for the target slave device in below rule: 

 

For BT HID profile, please encode: 

HID

<

MAC Address

> in Code39 without checksum or QR Code. 

 

For BT SPP profile, please encode: 

SPP

<

MAC Address

> in Code39 without checksum or QR Code. 

Summary of Contents for MT840

Page 1: ...MT840 User s Manual V1 1 MT840 2D Wireless Scanner User s Manual Version 1 1 DATE 2022 07 14...

Page 2: ...s to TAB ENTER ESCAPE 13 Function Code Conversion 14 Control Code Output Method 14 Numeric Key 16 Capslock Mode 16 Keyboard Layout 17 Intercharacter Delay 19 Interblock Delay 19 BCC Binary Check Chara...

Page 3: ...34 USB VCP 35 CHAPTER 4 READING MODE 36 TRIGGER MODE 36 TOGGLE MODE 36 CONTINUOUS MODE 36 AUTO SENSING MODE 37 ADVANCED READING MODE SETTINGS 38 LED Auto Off Timeout 38 Scan Interval 38 Identical Read...

Page 4: ...le Disable Code 32 53 Leading Tailing 53 CODABAR NW 7 54 Enable Disable Codabar 54 Verification 54 Start Stop 54 Codabar Min Max Length 55 INTERLEAVED 2 OF 5 56 Enable Disable Interleaved 2 of 5 56 Ve...

Page 5: ...70 CODE 128 GS1 128 71 Enable Disable Code 128 GS1 128 71 Code 128 GS1 128 Min Max Length 71 GS1 DATABAR RSS 14 72 Enable Disable GS1 DataBar 72 GS1 DATABAR LIMITED RSS LIMITED 72 Enable Disable GS1 D...

Page 6: ...APTER 6 APPENDIX 77 APPENDIX NUMBERS 77 APPENDIX UPPER CASE ALPHABETS 78 APPENDIX LOWER CASE ALPHABETS 80 APPENDIX CONTROL CODES 82 APPENDIX SYMBOLS 84 APPENDIX FUNCTION KEYS 87 APPENDIX NAVIGATION KE...

Page 7: ...o work with laptops tablets smart phones and other mobile devices with iOS Android and Windows Specifications Optic Performance Light Source White LED Visible red LED Sensor 640 x 480 Scan Rate 30 Fra...

Page 8: ...ing Current 210mA Standby Current 25mA Battery 3 7V 350mAh Li Polymer Battery Number of Scan per full charge 6 000 scans 1 scan 5 secs Bluetooth connected Connectivity Radio Bluetooth 5 0 dual mode Cl...

Page 9: ...ntal WEEE RoHS 2 0 Beeper Indication Beeper Status Single beep Good read Single short beep The scanner reads a Code39 ASCII during multi step configuration Two beeps Wireless connection The scanner su...

Page 10: ...MT840 User s Manual V1 1 10 LED Indication LED Status Off Power off Standby Connected Flashing green Disconnected Discoverable One green flash Good read Flashing red Low power Solid red Charging...

Page 11: ...s by scanning configuration barcodes in this manual Enable Barcode Configurability Disable Barcode Configurability Factory Default Scanning below configuration barcode will reset all parameters to fac...

Page 12: ...reading data barcode during multi step configuration you may cancel configuration by scanning below configuration barcode Abort Good Read Indicator Beep Tone Off Beep Low 2 0KHz Beep Medium 2 7KHz Be...

Page 13: ...Conversion please make sure that the application accepting barcode data supports Unicode display i g Word TeraTerm HT CR ESC Converts to TAB ENTER ESCAPE Off On Note 1 By default HT I CR M and ESC A i...

Page 14: ...r Keys Control Code Output Method Ctrl Mode Alt Mode Disable Output Note Control code 0x01 0x1A can be sent by two methods 1 Ctrl Mode A barcode of A HT F 0x41 0x09 0x46 is scanned the output sequence...

Page 15: ...trl a Alt 0 1 STX 02 2 Ctrl b Alt 0 2 ETX 03 3 Ctrl c Alt 0 3 EOT 04 4 Ctrl d Alt 0 4 ENQ 05 5 Ctrl e Alt 0 5 ACK 06 6 Ctrl f Alt 0 6 BEL 07 7 Ctrl g Alt 0 7 BS 08 8 Ctrl h Alt 0 8 HT 09 9 Ctrl i Alt...

Page 16: ...ded16 digits Scan NUMERIC KEY if you want to use the keys on the numeric keypad 2 If you select NUMERIC KEY the Num Lock status of the physical keyboard should be ON Capslock Mode Capslock Off Capsloc...

Page 17: ...MT840 User s Manual V1 1 17 Keyboard Layout English US English UK Danish Spanish Hungarian QWERTZ Hungarian QWERTY Canadian French Dutch Italian French German Swiss German Swiss French Swedish...

Page 18: ...MT840 User s Manual V1 1 18 Czech QWERTZ Czech QWERTY Norwegian Belgian Portuguese Slovak Brazilian QWERTY Canadian Traditional Japanese Alt Code...

Page 19: ...Scan Set Intercharacter Delay Step2 Scan 0 0 8 in Appendix Numbers Step3 Scan Set Intercharacter Delay Interblock Delay The configurable range is from 0 to 2550ms with 10ms increment The larger the nu...

Page 20: ...7h F1h However since control character cannot be displayed in Bluetooth HID USB HID BCC will be converted into 2 bytes of characters As a result the data will be TEST Enter F 1 GS Character Replacemen...

Page 21: ...sable Inverse Barcode Enable Inverse Barcode Chapter 3 Interface BT HID Getting Connected 1 Press the scan button to power up the scanner 2 Scan Disconnect the scanner will emit two beeps Alternativel...

Page 22: ...ile conneted with the scanner as physical keyboard the touch keyboard on iOS Android device might disappear To resolve this issue please do the following 1 For iOS device simply press the Scan Button...

Page 23: ...MT840 User s Manual V1 1 23 0 1 2 3 4 5 6 7 8 9 3 Scan Enter Enter 4 Scan Pincode Stop Pincode Stop...

Page 24: ...conflict BT SPP Master Auto reconnect BT SPP Slave No Auto reconnect 4 Select Wireless Scanner from discovered device list 5 If Bluetooth application prompts you to enter a pincode enter 1234 from th...

Page 25: ...0 0 in Appendix Numbers Step3 Scan Set SPP Pincode General Bluetooth Settings Power Off Timeout The power off timeout is 3 minutes 0 second by default They are configurable from a minimum of 10 secon...

Page 26: ...t Second To disable Power Off Timeout make scanner always on scan below barcode Disable Timeout Shut Down To shut down the scanner immediately pelase scan below configuration barcode Shut Down iOS Tou...

Page 27: ...equested by the host device which by default is 1234 for BT SPP profile and a random number generated by the host device for BT HID profile Enable SSP Disable SSP Set Bluetooth Device ID Bluetooth dev...

Page 28: ...ode Add MAC Address to Bluetooth Device ID Check Bluetooth Firmware Version To check scanner s Bluetooth firmware version please connect to a host device via BT HID or BT SPP and scan below configurat...

Page 29: ...is a connection method that turns the scanner into a master device which initiates the Bluetooth connection with the target host device now a slave device This as a result saves user the trouble of g...

Page 30: ...52 2C 3B Profile BT HID Encode HID001583522C3B in Code39 without checksum or QR Code Memory Mode Memory Mode After scanning the above barcode the scanner will be able to collect barcode data off line...

Page 31: ...y mode Delete Last Record To delete last memory data please scan below configuration barcode Delete Last Data Clear All Record To delete all memory data please connect the scanner to the host with USB...

Page 32: ...rator in memory mode is comma by default It can be replaced by any alphanumeric characters Field Separator Example Set Field Separator as Semicolon Step1 Scan Field Separator Step2 Scan in Appendix Sy...

Page 33: ...mat as MM DD YY Code 12 Step1 Scan Date Format Step2 Scan 1 2 respectively in Appendix Numbers Step3 Scan Date Format Time Format The default Time Format is HH MM SS Code 01 Time Format Below are avai...

Page 34: ...0 30 am HH MM SS Step1 Scan Set Date Step2 Scan 2 2 0 7 2 7 in Appendix Numbers Step3 Scan Set Date Step4 Scan Set Time Step5 Scan 0 8 1 0 3 0 in Appendix Numbers Step6 Scan Set Time USB HID To output...

Page 35: ...barcode data directly to host device via USB virtual COM interface please scan below configuration barcode Normally virtual COM port can be recognized by the host If it is not recognizable by the hos...

Page 36: ...pires Trigger Mode Toggle Mode In Toggle Mode the LED will stay on once trigger is pressed once and will turn off automatically when a barcode is read or LED Auto Off timeout expires Toggle Mode Conti...

Page 37: ...de In Auto sensing Mode the LED will turn on when image change is detected within scanner s field of view and will turn off when 1 a barcode is read 2 LED Auto Off timeout expires 3 trigger is pressed...

Page 38: ...Timeout to 10 sec Step1 Scan LED Auto Off Timeout Step2 Scan 2 4 in Appendix Numbers 01 0 1 sec 02 0 2 sec 03 0 3 sec 04 0 4 sec 05 0 5 sec 06 1 0 sec 07 1 5 sec 08 2 0 sec 09 2 5 sec 10 3 0 sec 11 3...

Page 39: ...s repetitive input of an identical data The configurable range is from 0 1 to 25 5 sec Identical Read Interval Default 1 sec Example Set Identical Read Interval to 10 sec Step1 Scan Identical Read Int...

Page 40: ...mat is as follows Preamble Code ID Barcode Length Barcode Data Postamble Terminator Code ID Disable Code ID Enable Factory ID Enable Set ID Set ID Set ID can be up to 2 alphanumerics for each symbolog...

Page 41: ...ed 2 of 5 Set ID Standard 2 of 5 Set ID Matrix 2 of 5 Set ID Industrial 2 of 5 Set ID Code11 Set ID China Postal Code Set ID MSI Plessey Set ID UK Plessey Set ID EAN 13 Set ID UPC A Set ID EAN 8 Set I...

Page 42: ...bar Expanded Set ID QR Code Set ID Micro QR Code Set ID PDF417 Set ID MicroPDF417 Set ID Data Matrix Set ID Aztec Set ID MaxiCode Set ID Hanxin Set ID Code 16K Example Set Code39 Set ID as XY Step1 Sc...

Page 43: ...Set Preamble as XYZ123 Step 1 Scan Set Preamble Step 2 Scan X Y Z 1 2 3 in Appendix Upper Case Alphabets Numbers Step 3 Scan Set Preamble Postamble Postamble can be up to 16 bytes of data Set Postambl...

Page 44: ...44 Clear Preamble Postamble Clear Preamble Postamble Terminator None LF CR CR LF TAB Space ESC Note 1 For USB HID BT HID interface the default terminator is CR 2 For USB VCP BT SPP interface the defa...

Page 45: ...Symbologies Disable All Symbologies Enable All 1D Symbologies Disable All 1D Symbologies Enable All 2D Symbologies Disable All 2D Symbologies Note When all symbologies are disabled configuration barc...

Page 46: ...heck Digit UPC A Expand to EAN 13 Enable UPC A Expand to EAN 13 Disable UPC A Expand to EAN 13 Add On Supplement Enable 5 digit Supplement Disable 5 digit Supplement Enable 2 digit Supplement Disable...

Page 47: ...an UPC A barcode that has 2 digit or 5 digit addenda supplement UPC E Enable Disable UPC E Enable UPC E Disable UPC E Check Digit Send Check Digit Not Send Check Digit Add On Supplement Enable 5 digi...

Page 48: ...enda Required is enabled the scanner will only read an UPC E barcode that has 2 digit or 5 digit addenda supplement EAN 8 Enable Disable EAN 8 Enable EAN 8 Disable EAN 8 Check Digit Not Send Check Dig...

Page 49: ...able Addenda Required Disable Addenda Required Note When Addenda Required is enabled the scanner will only read an EAN 8 barcode that has 2 digit or 5 digit addenda supplement EAN 13 Enable Disable EA...

Page 50: ...lement Disable 5 digit Supplement Enable 2 digit Supplement Disable 2 digit Supplement Enable Addenda Required Disable Addenda Required Note When Addenda Required is enabled the scanner will only read...

Page 51: ...MT840 User s Manual V1 1 51 Code 39 Enable Disable Code 39 Enable Code 39 Disable Code 39 Verification Disable CDV CDV Send CD CDV Not Send CD Start Stop Not Send Start Stop Send Start Stop...

Page 52: ...Length Default 01 Set Max Length Default 99 Example Set Min Length as 8 Max Length as 12 for Code39 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan S...

Page 53: ...MT840 User s Manual V1 1 53 Code 32 Enable Disable Code 32 Enable Code 32 Disable Code 32 Leading Tailing Not Send Leading Tailing Send Leading Only Send Tailing Only Send Leading Tailing...

Page 54: ...MT840 User s Manual V1 1 54 Codabar NW 7 Enable Disable Codabar Enable Codabar Disable Codabar Verification Disable CDV CDV Send CD CDV Not Send CD Start Stop Send Start Stop Not Send Start Stop...

Page 55: ...efault 99 Example Set Min Length as 8 Max Length as 12 for Codabar Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 in Ap...

Page 56: ...MT840 User s Manual V1 1 56 Interleaved 2 of 5 Enable Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Verification Disable CDV CDV Send CD CDV Not Send CD...

Page 57: ...efault 32 Example Set Min Length as 8 Max Length as 12 for Interleaved 2 of 5 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Sca...

Page 58: ...MT840 User s Manual V1 1 58 Standard 2 of 5 IATA Enable Disable Standard 2 of 5 Enable Standard 2 of 5 Disable Standard 2 of 5 Verification Disable CDV CDV Send CD CDV Not Send CD...

Page 59: ...efault 32 Example Set Min Length as 8 Max Length as 12 for Standard 2 of 5 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1...

Page 60: ...MT840 User s Manual V1 1 60 Matrix 2 of 5 Enable Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable Matrix 2 of 5 Verification Disable CDV CDV Send CD CDV Not Send CD...

Page 61: ...efault 32 Example Set Min Length as 8 Max Length as 12 for Matrix 2 of 5 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2...

Page 62: ...MT840 User s Manual V1 1 62 Industrial 2 of 5 Enable Disable Industrial 2 of 5 Enable Industrial 2 of 5 Disable Industrial 2 of 5 Verification Disable CDV CDV Send CD CDV Not Send CD...

Page 63: ...h as 8 Max Length as 12 for Industrial 2 of 5 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 in Appendix Numbers Step6...

Page 64: ...gth Set Min Length Default 04 Set Max Length Default 32 Example Set Min Length as 8 Max Length as 12 for Code11 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length S...

Page 65: ...MT840 User s Manual V1 1 65 China Postal Code Enable Disable China Postal Code Enable China Postal Code Disable China Postal Code Verification Disable CDV CDV Send CD CDV Not Send CD...

Page 66: ...efault 32 Example Set Min Length as 8 Max Length as 12 for China Postal Code Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan...

Page 67: ...0 User s Manual V1 1 67 MSI Plessey Enable Disable MSI Plessey Enable MSI Plessey Disable MSI Plessey Verification Send Check Digit Not Send Check Digit Single Check Digit MOD10 Double Check Digits MO...

Page 68: ...efault 32 Example Set Min Length as 8 Max Length as 12 for MSI Plessey Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 i...

Page 69: ...MT840 User s Manual V1 1 69 UK Plessey Enable Disable UK Plessey Enable UK Plessey Disable UK Plessey Check Digit Send Check Digit Not Send Check Digit...

Page 70: ...ngth Default 01 Set Max Length Default 99 Example Set Min Length as 8 Max Length as 12 for Code93 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set...

Page 71: ...Length Set Min Length Default 01 Set Max Length Default 99 Example Set Min Length as 8 Max Length as 12 for Code128 GS1 128 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set...

Page 72: ...GS1 DataBar Disable GS1 DataBar GS1 DataBar Limited RSS Limited Enable Disable GS1 DataBar Limited Enable GS1 DataBar Limited Disable GS1 DataBar Limited GS1 DataBar Expanded RSS Expanded Enable Disab...

Page 73: ...0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 01 99 Surround G...

Page 74: ...QR Code Enable Disable QR Code Enable QR Code Disable QR Code Micro QR Code Enable Disable Micro QR Code Enable Micro QR Code Disable Micro QR Code Data Matrix Enable Disable Data Matrix Enable Data...

Page 75: ...r s Manual V1 1 75 PDF417 Enable Disable PDF417 Enable PDF417 Disable PDF417 MicroPDF417 Enable Disable MicroPDF417 Enable MicroPDF417 Disable MicroPDF417 Aztec Enable Disable Aztec Enable Aztec Disab...

Page 76: ...r s Manual V1 1 76 MaxiCode Enable Disable MaxiCode Enable MaxiCode Disable MaxiCode Hanxin Enable Disable Hanxin Enable Hanxin Disable Hanxin Code 16K Enable Disable Code 16K Enable Code 16K Disable...

Page 77: ...MT840 User s Manual V1 1 77 Chapter 6 Appendix Appendix Numbers 0 1 2 3 4 5 6 7 8 9...

Page 78: ...MT840 User s Manual V1 1 78 Appendix Upper Case Alphabets A B C D E F G H I J K L M N O P...

Page 79: ...MT840 User s Manual V1 1 79 Q R S T U V W X Y Z...

Page 80: ...MT840 User s Manual V1 1 80 Appendix Lower Case Alphabets a b c d e f g h i j k l m n o p...

Page 81: ...MT840 User s Manual V1 1 81 q r s t u v w x y z...

Page 82: ...MT840 User s Manual V1 1 82 Appendix Control Codes NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI...

Page 83: ...MT840 User s Manual V1 1 83 DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US...

Page 84: ...MT840 User s Manual V1 1 84 Appendix Symbols _...

Page 85: ...MT840 User s Manual V1 1 85...

Page 86: ...MT840 User s Manual V1 1 86 SP DEL...

Page 87: ...MT840 User s Manual V1 1 87 Appendix Function Keys F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Home End Enter Numeric Key App...

Page 88: ...MT840 User s Manual V1 1 88 Appendix Navigation Keys Cursor Left Cursor Right Cursor Up Cursor Down Page Up Page Down Tab Back Tab Esc Enter BS Ins Del...

Page 89: ...1 1 89 Appendix Modifier Keys Alt Left make 1 Alt Left break Alt Right make Alt Right break Shift Left make 2 Shift Left break Shift Right make Shift Right break Win Left make Win Left break Win Right...

Page 90: ...sume barcode setting 2 When Shift Left make is programmed please scan Shift Left break to resume barcode setting 3 When Ctrl Left make is programmed please scan Ctrl Left break to resume barcode setti...

Page 91: ...ck Mode OFF Keyboard Layout English US Intercharacter Delay 4ms Interblock Delay 0ms BCC Binary Check Character OFF GS Character Replacement OFF Define Replacement Character N A Imaging Settings Inver...

Page 92: ...Disable Code ID Set ID N A Data Length OFF Preamble N A Postamble N A Terminator CR BT HID USB HID CR LF BT SPP USB VCP Symbologies General Settings N A UPC A Enable Disable ON Check Digit Send UPC A...

Page 93: ...99 Code 32 Enable Disable OFF Leading Tailing Send Leading Tailing Codabar Enable Disable ON Verification Disable CDV Start Stop Not Send Min Length 01 Max Length 99 Interleaved 2 of 5 Enable Disable...

Page 94: ...Length 32 MSI Plessey Enable Disable OFF Verification Send Check Digit Single Check Digit MOD10 Min Length 04 Max Length 32 UK Plessey Enable Disable OFF Check Digit Not Send Code 93 Enable Disable O...

Page 95: ...OFF QR Code Enable Disable ON Micro QR Code Enable Disable ON Data Matrix Enable Disable ON PDF 417 Enable Disable ON Micro PDF 417 Enable Disable ON Aztec Enable Disable OFF MaxiCode Enable Disable...

Page 96: ...4 6 Code32 B 42 7 Codabar N 4E 8 Interleaved 2 of 5 I 49 9 Standard 2 of 5 IATA R 52 10 Matrix 2 of 5 Y 59 11 Industrial 2 of 5 V 56 12 Code 11 J 4A 13 China Postal Code Toshiba Code H 48 14 MSI Pless...

Page 97: ...MT840 User s Manual V1 1 97 23 MicroPDF417 Z 5A 24 Aztec z 7A 25 MaxiCode Z 5A 26 Hanxin X 58 27 Code 16K 16 31 36...

Page 98: ...ine Feed 0B 11 VT Vertical Tab 0C 12 FF Form Feed 0D 13 CR Carriage Return 0E 14 SO Shift Out 0F 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13...

Page 99: ...nthesis 2A 42 Asterisk 2B 43 Plus 2C 44 Comma 2D 45 Minus Dash 2E 46 Dot 2F 47 Forward Slash 30 48 0 31 49 1 32 50 2 33 51 3 34 52 4 35 53 5 36 54 6 37 55 7 38 56 8 39 57 9 3A 58 Colon 3B 59 Semi colo...

Page 100: ...57 87 W 58 88 X 59 89 Y 5A 90 Z 5B 91 Left Opening Bracket 5C 92 Back Slash 5D 93 Right Closing Bracket 5E 94 Caret Circumflex 5F 95 _ Underscore 60 96 Grave Accent 61 97 a 62 98 b 63 99 c 64 100 d 6...

Page 101: ...840 User s Manual V1 1 101 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7A 122 z 7B 123 Left Opening Brace 7C 124 Vertical Bar 7D 125 Right Closing Brace 7E 126 Tilde 7F 127 DEL Dele...

Page 102: ...nual V1 1 102 Version History Rev Date Description Issued 1 0 2022 06 09 Initial Release Shaw 1 1 2022 07 14 Added Control Code Output Method GS Character Replacement Surround GS1 AI s with Parenthese...

Reviews: