OSD Timeout
Use the OSD Timeout setting to set the amount of time you would like to see the Menu on screen. Selectable values range
from
5
to
30 Seconds
in 5 second increments. A value of
None
allows the menu to stay on screen until it is manually exited.
IMD Config Submenu
■
Overview
The V-R902DLW features an In-Monitor Display (IMD) with the ability to display on-screen text and tally in three colors. IMD
text, color, and alignment can be assigned to each screen locally using menu options (see below). Alternately, IMD text and
tally can be remotely controlled via the RS-422/485 serial interface using several industry-standard protocols, including TSL
v4.0 and Image Video. Multiple V-R902DLW monitors can be looped together and each addressed individually via the
protocol. All menu features of the V-R902DLW can also be controlled via the Marshall Network Controller box using MEI
protocol. (Contact Marshall Electronics for additional information).
Use the IMD Configuration submenu to configure various IMD parameters as described below.
■
IMD ID #
The IMD ID # identifies each screen to the controlling device. When using the TSL protocol, the ID # of each screen should be
manually set in conjunction with the controlling device. When using the Image Video protocol, the ID # may be set
automatically by the controlling device, after each IMD is initially identified by IMD Name (see “IMD Name[S/N]” below).
Available ID #s are
000-254
.
■
IMD Group #
Each screen can be assigned an IMD Group # when using the Marshall protocol. Available Group #s are
01-254
.
■
IMD Protocol
Use the IMD Protocol menu option to choose the protocol with which the V-R902DLW receives remote commands. Currently,
four protocols are available. Contact Marshall Electronics for the latest protocol compatibility.
Image Video
Use the Image Video protocol setting when controlling the IMD from an Image Video tally controller (e.g. TSI-1000) or
other controlling device which utilizes the Image Video protocol. The
IMD #
,
IMD Name(S/N)
, and
Baud Rate
parameters must be set for each screen in conjunction with the controlling device.
IMD Configuration Submenu