Product Specification
Model Number
Marsden PT-700
Capacity/Division
2000kg x 500g
Inner Resolution
1 million
Weight of Scale
Approximately 125kg
Dimensions
Length
– 1470mm Width – 545mm Width between forks – 220mm Fork to ground
78mm
Indicator
HL318L with 6-digit 32cm LED display and seven function keys
Protection Level
IP5X
Battery
6V4Ah
Adaptor
Voltage
– 100-240VAC Current – 0.1A
Operating Temperature
-
10˚C - 40˚C
Print Output
Weight, count, net weight, gross weight, tare weight, accumulation
Please note:
Marsden’s policy is one of continuous development and therefore we reserve the right to change product
specification without notice.
Safety Instructions
Before using the scale, please read with care the information given in this user manual, which contains important instructions
for proper installation, use and maintenance.
Marsden/the manufacturer shall not be liable for damages arising from failure to heed the following instructions:
•
When using electrical components under increased safety requirements, always comply with appropriate regulations.
•
Inappropriate installation/use will render the warranty null and void.
•
Ensure the voltage marked on the power supply unit matches your mains supply.
•
This product is not waterproof. While it can be used outside, we do not recommend using the scale in humid, damp
or wet environments.
•
Observe the permissible ambient temperatures for use.
•
The device meets the requirements for electromagnetic capability. Do not exceed the maximum values specified in
the applicable standards.
If you have any problems, contact Marsden/your local dealer/your service partner.
Cleaning
•
Please do not use corrosive liquids or large amounts of water to clean the scale.
•
Always disconnect the scale from the mains power supply before cleaning.
Maintenance
•
The scale does not require routine maintenance. However, we recommend checking accuracy regularly. If
inaccuracies occur, please contact your service partner.
•
If you’re in the UK, you can book an accuracy check with the Marsden Service team. Email
Before Using the Scale
•
The scale’s indicator, the I-400-APP, must be connected to the mains for operation.
•
Ensure the indicator and scale are connected via the cables provided prior to use.
•
Once switched on, the scale is only ready to use once the display shows 0.000.
•
This scale is fitted with adjustable levelling feet. Please adjust these accordingly to ensure the scale is level. An unlevel
surface could result in inaccurate readings.